April 2016 Service ManualChecklist B ProceduresPart No. 139234 Z-34/22 Bi-Energy 29B-3Inspect the Electrical WiringGenie specifications require that this procedure beperformed every 250 hours or quarterly, whichevercomes first.Maintaining electrical wiring in good condition isessential to safe operation and good machineperformance. Failure to find and replace burnt,chafed, corroded or pinched wires could result inunsafe operating conditions and may causecomponent damage.Electrocution/burn hazard.Contact with electrically chargedcircuits could result in death orserious injury. Remove all rings,watches and other jewelry.1 Inspect the following areas for burnt, chafed,corroded pinched and loose wires:• Engine compartment• Engine wiring harness• Hydraulic manifold wiring• Inside of the ground control box2 Open the ground controls side turntable cover.3 Start the engine from the ground controls andraise the secondary boom above the turntablecovers.4 Remove the center turntable cover retainingfasteners. Remove the center turntable coverfrom the machine.5 Inspect the turntable area for burnt, chafedand pinched cables.6 Lower the secondary boom to the stowedposition and turn the engine off.7 Inspect the following areas for burnt, chafed,corroded pinched and loose wires:• Cable track on the primary boom• Cables on the primary, secondary and jibbooms• Inside of the platform control box8 Inspect for a lite, even coating of dielectricgrease in the following locations:• All wire harness connectors to platformcontrol boxNote: Do not apply excessive amounts of dielectricgrease to harness connectors, pins or sockets.Note: Do not apply dielectric grease to a engineECU/ECM or engine harness connectors.