MIM-16FSW/MIM-16FSW-PoE/DMIM-24FSW/DMIM-24FSW-PoE 127Figure 144 T1 cableFor the pinouts of T1 cables, see Low-End and Mid-Range Series Routers CableManual.c CAUTION: The corresponding cables are not included in the standard shipmentpackage of MIM-1VT1. Please order them together with MIM-1VT1. By default,they are not supplied.Connecting the InterfaceCablec CAUTION:■ You should connect a cable to the port with the correct mark. Misplugging isprone to impair the card and even damage the router.■ When using T1 cable outdoors, you are recommended to install a speciallightning arrester on the input end of the cable in order to avoid lightning moreeffectively.If the MIM has been properly installed, follow these steps to connect the cable:Step 1: Plug one end of T1 cable into the RJ45 connector of MIM-1VT1.Step 2: Connect the other end of T1 cable to the peer device;Step 3: Check the status of LINK LED on the MIM-1VT1 panel: OFF means the linkis not connected. In the latter case, check the line.MIM-16FSW/MIM-16FSW-PoE/DMIM-24FSW/DMIM-24FSW-PoEIntroduction The 16/24-port 10/100 Mbps Ethernet Layer 2 switching MIM interface modules(MIM-16FSW/MIM-16FSW-PoE and DMIM-24FSW/DMIM-24FSW-PoE) areapplicable to MSR 30 series routers. A router installed with MIM-16FSW orDMIM-24FSW can work as a switching/routing integrated device on a small-sizedenterprise network to connect PCs and network devices inside the networkdirectly. MIM-16FSW-PoE/DMIM-24FSW-PoE can supply power to PDs throughPoE.The interfaces provided on the MIM-16FSW and DMIM-24FSW module are asfollows:■ 16 × 10/100 Mbps RJ45 connector interfaces on the MIM-16FSW module