135Parametersslot slot-number: Displays the temperature information of the sensors on the specified member device.The slot-number argument is the ID of a member device of the current IRF virtual device.|: Filters command output by specifying a regular expression. For more information about regularexpressions, see the Fundamentals Configuration Guide.begin: Displays the first line that matches the specified regular expression and all lines that follow.exclude: Displays all lines that do not match the specified regular expression.include: Displays all lines that match the specified regular expression.regular-expression: Specifies a regular expression, which is a case-sensitive string of 1 to 256 characters.DescriptionUse the display environment command to display the temperature information of the device, includingthe current temperature and temperature thresholds.If both slot and vent are not provided, all sensors on the IRF member device are specified.Examples# Display temperature information about the device. display environmentSystem Temperature information (degree centigrade):----------------------------------------------------SlotNo Temperature Lower limit Upper limit1 39 0 55Table 19 Output descriptionField DescriptionSlotNO ID or a member deviceTemperature Current temperatureLower limit Temperature lower limitUpper limit Temperature upper limitdisplay fanSyntaxdisplay fan [ slot slot-number [ fan-id ] ] [ | { begin | exclude | include } regular-expression ]ViewAny viewDefault level1: Monitor levelParametersslot slot-number: Displays the operating state of fans of the specified member device. The slot-numberargument is the ID of a member device of the current IRF virtual device. If the slot-number argument is notprovided, the system displays the operating state of fans of all member devices.