143System failure handling method: rebootdisplay transceiverSyntaxdisplay transceiver { interface [ interface-type interface-number ] } [ | { begin | exclude | include }regular-expression ]ViewAny viewDefault level2: System levelParametersinterface [ interface-type interface-number ]: Displays main parameters of the pluggable transceiverplugged in the specified interface. interface-type interface-number represents interface type andinterface number. If it is not specified, the command displays main parameters of the pluggabletransceiver(s) in all the interfaces.|: Filters command output by specifying a regular expression. For more information about regularexpressions, see the Fundamentals Configuration Guide.begin: Displays the first line that matches the specified regular expression and all lines that follow.exclude: Displays all lines that do not match the specified regular expression.include: Displays all lines that match the specified regular expression.regular-expression: Specifies a regular expression, which is a case-sensitive string of 1 to 256 characters.DescriptionUse the display transceiver command to display main parameters of a single or all pluggabletransceivers.Examples# Display main parameters of the pluggable transceiver plugged in interface GigabitEthernet 1/0/3.(The output of this command varies with devices.) display transceiver interface gigabitethernet1/0/3GigabitEthernet1/0/3 transceiver information:Transceiver Type : 1000_BASE_SX_SFPConnector Type : LCWavelength(nm) : 850Transfer Distance(m) : 550(50um),270(62.5um)Digital Diagnostic Monitoring : YESVendor Name : H3COrdering Name : SFP-GE-SX-MM850Table 24 Output descriptionField Descriptiontransceiver information Pluggable transceiver informationTransceiver Type Pluggable transceiver type