148begin: Displays the first line that matches the specified regular expression and all lines that follow.exclude: Displays all lines that do not match the specified regular expression.include: Displays all lines that match the specified regular expression.regular-expression: Specifies a regular expression, which is a case-sensitive string of 1 to 256 characters.DescriptionUse the display transceiver diagnosis command to display the currently measured value of digitaldiagnosis parameters of H3C customized anti-spoofing pluggable optical transceivers.Examples display transceiver diagnosis interface gigabitethernet1/0/2GigabitEthernet1/0/2 transceiver diagnostic information:Current diagnostic parameters:Temp(°C) Voltage(V) Bias(mA) RX power(dBM) TX power(dBM)36 3.31 6.13 -35.64 -5.19Table 27 Output descriptionField Descriptiontransceiver diagnostic information Digital diagnosis information of the transceiver plugged inthe interfaceCurrent diagnostic parameters Current diagnostic parametersTemp.(°C) Digital diagnosis parameter-temperature, in °C, with theprecision to 1°C.Voltage(V) Digital diagnosis parameter-voltage, in V, with theprecision to 0.01 V.Bias(mA) Digital diagnosis parameter-bias current, in mA, with theprecision to 0.01 mA.RX power(dBM) Digital diagnosis parameter-RX power, in dBM, with theprecision to 0.01 dBM.TX power(dBM) Digital diagnosis parameter-TX power, in dBM, with theprecision to 0.01 dBM.display transceiver manuinfoSyntaxdisplay transceiver manuinfo { interface [ interface-type interface-number ] } [ | { begin | exclude |include } regular-expression ]ViewAny viewDefault level2: System levelParametersinterface [ interface-type interface-number ]: Displays part of the electrical label information of the H3Ccustomized anti-spoofing pluggable transceiver plugged in the specified interface. interface-type