75Connecting cables to the copper ports on the interface cardsThe LSWM2XGT2PM and LSWM2XGT8PM interface cards provide copper ports. To connect cables tothe copper ports on the LSWM2XGT2PM and LSWM2XGT8PM interface cards, follow these guidelines:• Use Category-6A or above cables and connectors. The max transmission distance varies by cabletype:{ Category-6 UTP—55 m (180.45 ft).{ Category-6 STP—100 m (328.084 ft), no interference.{ Category-6 SFTP—100 m (328.084 ft).{ Category-6A and above twisted pair—100 m (328.084 ft).• Do not bundle cables in their first 20 m (65.62 ft).• Separate power cords and twisted pair cables at and around the distribution frame.• For ports adjacent to one another on the device, the peer ports on the distribution frame ispreferably not adjacent, for example:{ If the device connects to one distribution frame, connect port 1 on the device to port 1 on thedistribution frame and port 2 on the device to port 3 on the distribution frame.{ If the device connects to two distribution frames, connect port 1 on the device to port 1 ondistribution frame 1 and port 2 on the device to port 1 on distribution frame 2.• Keep the device and twisted pair cables away from the interference source, such as a two-wayradio and a high-power variable-frequency drive.