5 - Operation72Quick Reference - Cleaning÷ NOTE! Pump speed 250-280 rpm.A. Turn On.B. Turn Off.C. Minimum 45 seconds with nozzle Off.D. Spray until air comes out of nozzles. When pressure drops, close regulation valve by pressing the button, untilyellow LED lights on the valve. When the boom is completely empty, press the button for a few seconds to avoidpressure spike.Standard Cleaningμ ATTENTION! For cleaning between spray jobs where crops are not very sensitive towards chemicals just sprayed.1. Engage pump with tractor in idle, so that pump speed is as low as possible (250/550 rpm, depending on pump type).2. Turn suction valve towards and the pressure SmartValve towards while sucking approximately 1/6 of therinse tank content into the main tank. It is important to have full agitation for approximately 20 seconds, and then closeagitation valve completely.3. Turn suction valve towards and the pressure SmartValve towards with all sections off for approximately 45seconds.4. Turn all sections on. Spray until air comes out of nozzles. When pressure drops, close regulation valve by pressing thebutton, until yellow LED lights on the valve. When the boom is completely empty, press the button for a fewseconds to avoid pressure spike.Repeat the following 3 steps 5 times:1. Turn suction valve towards and the pressure SmartValve towards while sucking approximately 1/6 of therinse tank content into the Main tank.2. Turn suction valve towards and the pressure SmartValve towards with all sections off for approximately 45seconds.3. Turn all sections on. Spray until air comes out of nozzles. When pressure drops, close regulation valve by pressing thebutton, until yellow LED lights on the valve. When the boom is completely empty, press the button for a fewseconds to avoid pressure spike.5 x 1/65 x 1/61/61/6A B CCDD