Note: See “System” on page 108 to determine which components a field service technician should replace.Error code/symptom FRU/action1600(The system management processor is notfunctioning) Before replacing a FRU,remove the ac power to the server, wait 20seconds; then, reconnect the ac power.Wait 30 seconds; then, turn on the server.System board1601(The system is able to communicate to thesystem management processor, but thesystem management processor failed torespond at the start of POST.) Completethe following steps before replacing aFRU:1. Remove the ac power to the server,wait 20 seconds; then, reconnect theac power. Wait 30 seconds; then, turnon the server.2. Flash update the system managementprocessor.1. Remote Supervisor Adapter, if installed2. System board1602(Optional service processor not properlyinstalled.)Disconnect all server and option power cords from server, wait 30seconds, reconnect, and retry.1762(Hard disk configuration error) 1. Hard disk drive.2. Hard disk cables.3. Run the Configuration/Setup Utility program.4. Hard disk adapter.5. SCSI backplane.6. System board.178X(Fixed disk error) 1. Hard disk cables.2. Run diagnostics.3. Hard disk adapter.4. Hard disk drive.5. System board.1800(No more hardware interrupt available forPCI adapter)1. Run the Configuration/Setup Utility program.2. Failing adapter.3. System board.1962(Drive does not contain a valid bootsector)1. Verify that a startable operating system is installed.2. Run diagnostics.3. Hard disk drive.4. SCSI backplane.5. Cable.6. System board.2400(Video controller test failure) 1. Video adapter (if installed)2. System board2462(Video memory configuration error) 1. Video adapter (if installed)2. System boardChapter 6. Symptom-to-FRU index 81