11. Type 1 and press Enter to continue.Attention: Do not restart or turn off the server until the update is completed.12. When the update is completed, turn off the server.13. Disconnect the server from the ac power source.14. Move the J14 jumper back to pins 1 and 2 to return to startup from the primarypage.15. Wait 30 seconds; then, connect the server to the ac power source.16. Replace the cover; then, restart the server.System-error log messagesA system-error log is generated only if a Remote Supervisor Adapter II SlimLine isinstalled. The system-error log can contain messages of three types:Information Information messages do not require action; they record significantsystem-level events, such as when the server is started.Warning Warning messages do not require immediate action; they indicatepossible problems, such as when the recommended maximumambient temperature is exceeded.Error Error messages might require action; they indicate system errors,such as when a fan is not detected.Each message contains date and time information, and it indicates the source ofthe message (POST/BIOS or the service processor).Note: The BMC log, which you can view through the Configuration/Setup Utilityprogram, also contains many information, error, and warning messages.In the following example, the system-error log message indicates that the serverwas turned on at the recorded time.- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Date/Time: 2002/05/07 15:52:03DMI Type:Source: SERVPROCError Code: System Complex Powered UpError Code:Error Data:Error Data:- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -The following table describes the possible system-error log messages andsuggested actions to correct the detected problems.v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 3, “Parts listing, Type 8872 and Type 8874,” on page 93 to determine which components arecustomer replaceable units (CRU) and which components are field replaceable units (FRU).v If an action step is preceded by “(Trained service technician only),” that step must be performed only by atrained service technician.System-error log message Action1.5V Calgary PLL Power Good Fault 1. Reseat the I/O board.2. Reseat the microprocessor tray.3. (Trained service technician only) Replace the PCI-X board.78 IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874: Problem Determination and Service Guide