800b0008-1301ffff Redundancy [RedundancySetElementName] has been restored. (Power Unit)Explanation: This message is for the use case when an implementation has detected Redundancy was Restored.May also be shown as 800b00081301ffff or 0x800b00081301ffffSeverity: InfoAlert Category: Warning - Redundant Power SupplyServiceable: NoCIM Information: Prefix: PLAT and ID: 0561SNMP Trap ID: 10Automatically notify Support: NoUser response: No action; information only.800b0108-1301ffff Redundancy Lost for [RedundancySetElementName] has asserted. (Power Unit)Explanation: This message is for the use case when Redundancy Lost has asserted.May also be shown as 800b01081301ffff or 0x800b01081301ffffSeverity: ErrorAlert Category: Critical - Redundant Power SupplyServiceable: YesCIM Information: Prefix: PLAT and ID: 0802SNMP Trap ID: 9Automatically notify Support: NoUser response:1. Check the LEDs for both power supplies.2. Follow the actions in Power-supply LEDs.800b010a-1e81ffff Redundancy Lost for [RedundancySetElementName] has asserted. (Fan Zone 1)Explanation: This message is for the use case when Redundancy Lost has asserted.May also be shown as 800b010a1e81ffff or 0x800b010a1e81ffffSeverity: ErrorAlert Category: Critical - Fan FailureServiceable: YesCIM Information: Prefix: PLAT and ID: 0802SNMP Trap ID: 11Automatically notify Support: NoUser response:1. Make sure that the connectors on fan n are not damaged.2. Make sure that the fan n connectors on the system board are not damaged.3. Make sure that the fans are correctly installed.4. Reseat the fans.5. Replace the fans. (n = fan number)800b0008-1301ffff • 800b010a-1e81ffff412 System x3650 M5 Type 5462: Installation and Service Guide