16 Global Settings | IDS X Series Training V2.31. Programming zones using both the string and bitmapped methods.a. Let‟s program zones 9 to 16 using the string method and zones 17 to 24 using the bitmapped sub-locaton methodb. The table describes what type of zone each one will beZone Type Value Zone Type Value9 Secondary Entry / Exit 08 17 Entry / Exit 0110 Follower 02 18 Follower 0211 Follower 02 19 Instant 0412 Instant 04 20 Instant 0413 Instant 04 21 Follower 0214 Outdoor Instant 15 22 Follower 0215 Outdoor Instant 15 23 Outdoor Instant 1516 Panic 03 24 Panic 03c. To program zones 9 to 16 into the system via the string method:Instructions Key pressesEnter installer mode [#] [9] [9] [9] [9] [*]Enter the location 2 [2] [*]Type in the complete string of information for allzones[0][8] [0][2] [0][2] [0][4] [0][4] [1][5] [1][5] [0][3] [*]d. Programming zones 7 and 8 using the sub-location method:Instructions Key pressesEnter location 1 [1] [*]Enter the sub-location number for zone 7 and press the [*] key [7] [*]Enter the value for an external instant zone followed by the [*] key.) [1] [5] [*]Now zone 8 [8] [*]Panic zone [0] [3] [*]To exit location 1 press the [#] key [#]Note: You will still be installer modeGlobal SettingsLocation 10: Zone Shutdown CountLocation Type: StandardThis option monitors the zone for the number of times it violates when the system is armed. Once thenumber of violations reaches the number entered in this location, the zone is automatically bypassed.Each partition has an option to enable any zones belonging to the partition that were bypassed due to thisoption in locations 221 to 228 depending on the partition.Valid Range: 1 - 15Default: 5Location 11: Programmable Zone Loop Response TimeLocation Type: StandardThis is the time that the zone must be violated before the zone will register a violation.Valid Range: 1 - 255Default: 2