IDS X Series Training V2.3 | Hardware 5Hardware1. Kick Start JumperWhen connecting to a battery, without 16VAC connected, the X-Series willnot power up until the kick start jumper has been shorted for a second. Thisfeature has been included so that if the battery voltage starts fluctuating andgoes below 10.5 volts, without AC, the panel switches off, stopping thealarm from entering any undesirable states that could compromise theintegrity of the system. When AC is applied the alarm will power upautomatically.2. Default button & 3. Panel Status LEDTo default the panel, physically remove power from the unit and press down thedefault button. Replace power whilst still holding down the button. Wait until thepanel status LED flashes once and then release the button.The status LED indicates the condition of the operating system.4. Serial OutputThe serial output is for connecting the voice module, serial communicators and direct download device.1. Kick Start7. Connectors5. Outputs3. Status LEDFigure 1 X-Series Alarm Panel6. OnboardExpander Connector4. Serial OutK/START2. Default ButtonSerial ConnectorGroundRxTxDefault ButtonPanel Status LED