32 Partition Options | IDS X Series Training V2.3Partition OptionsThe X-Series alarm panels have eight partitions that can have a number of zones and users allocated tothem. A partition is a separately controlled group of zones. Zones can be unique to the partition or can beshared between partitions for areas that are common.Location 201 to 208: Placing Zones into a PartitionLocation Type: BitmapBy default only the first eight zones are placed into partition one and any added zones must be allocatedto a partition.Valid Range: 01 - 64Exercise:Zones 10 to 16 need to be programmed into partition 2Instructions Key pressesTo allocate all the zones that we configured in sections c and dto partition 1 enter location 201[2][0][2] [*]The green READY LED should be on the and ARM, AWAY andPOWER LEDs should be offThis is a bitmapped location so data is entered by entering thezone number of the zone you want to allocate to the partition[9] [*] [1][0] [*] [1][1] [*] [1][2] [*] [1][3][*] [1][4] [*] [1][5] [*] [1][6] [*]Zone 9 to 16 LEDs should now be onExit location 202 [#]Note: When using an LED keypad to gain access to zones 17 onwards press the [*] key to pageto the next sixteen zones.The diagrams below show which page is being displayed via the keypad LEDs and whichzones they represent for the X64Curve keypad LEDsZones: 1 to 16 17 to 32 33 to 48 49 to 64Classic keypad LEDsLocation Partition DefaultZonesLocation Partition DefaultZonesLocation Partition DefaultZones201 1 1 to 8 204 4 207 7202 2 205 5 208 8203 3 206 6Location Partition DefaultZonesLocation Partition DefaultZonesLocation Partition DefaultZones201 1 1 to 8 204 4 207 7202 2 205 5 208 8203 3 206 6