Section: 8IDS X64 LCD Keypad User Manual 700-411-01C Issued August 2010204. Press the [*] key.5. The LCD display reads „User Code + *‟.6. Enter the [USER CODE] followed by the [*] key.7. The LCD display reads „Output No. + *‟.8. Enter the [OUTPUT No] followed by the [*] key.9. The LCD display reads „Action + *‟.10. Enter the [OUTPUT ACTION] followed by the [*] key.11. Repeat steps 6 - 10 until all the user outputs have been entered.12. Press the [#] key to exit the User Program Mode.Table 3: Output Address Physical Mapping DataAddress Physical Outputs Address Physical Outputs00 Disabled 21 Reserved01 Onboard output 1 22 Reserved02 Onboard output 2 23 Reserved03 Onboard output 3 24 Reserved04 Onboard output 4 25 Reserved05 Onboard output 5 26 Reserved06 Zone expander 1 output 1 27 Reserved07 Zone expander 1 output 2 28 Reserved08 Zone expander 2 output 1 29 Reserved09 Zone expander 2 output 2 30 Reserved10 Zone expander 3 output 1 31 Reserved11 Zone expander 3 output 2 32 Reserved12 Zone expander 4 output 1 33 Reserved13 Zone expander 4 output 2 34 Keypad 1 output14 Zone expander 5 output 1 35 Keypad 2 output15 Zone expander 5 output 2 36 Keypad 3 output16 Zone expander 6 output 1 37 Keypad 4 output17 Zone expander 6 output 2 38 Keypad 5 output18 Reserved 39 Keypad 6 output19 Reserved 40 Keypad 7 output20 Reserved 41 Keypad 8 outputTable 4: Output Actions DataValue Output Action00 Set Output High (Set)01 Set Output Low (Reset)02 Pulse Output High03 Pulse Output Low8.3.10 Option 14 – User Reporting Codes Enable[MASTER CODE] [*] [1] [4] [*] [USER CODE] [*] [BITMAP] [*] [#]1. Enter the User Program Mode as per steps 1 - 4 of section 8.2.2. The LCD display reads „Option Menu‟, „Add User Code‟.