Section: 8IDS X64 LCD Keypad User Manual 700-411-01C Issued August 2010 23NOTE:When you are at step 6, entering a zone number, you can use the following options to copy or delete azone name:[0] [*] Copy All – this is used to update the zone names to all keypads connected to the X64Alarm Panel. This is used when a keypad has been replaced or a new keypad is addedto the panel. (This can be used when you replace a keypad and want it to display theexisting zone names).[111] [*] Delete Name – this is used to delete the zone name being viewed from the X64 AlarmPanel.[222] [*] Delete All – this option is used to delete all zone names from the X64 Alarm Panel.8.3.13 Option 40 - Edit the Time[*] [MASTER CODE] [*] [4] [0] [*] [TIME] [*] [#]1. Enter the User Program Mode as per steps 1 - 4 of section 8.2.2. The LCD display reads „Option Menu‟, „Add User Code‟.3. To select menu option 40 – „Edit Time‟, press the [4] [0] keys followed by the [*] key oralternatively use the [PANIC] or [MED] keys to scroll through the list of programmable optionsuntil you reach the option you want.4. Press the [*] key.5. The LCD display reads „New Time?‟.6. Enter the [TIME] that you wish to edit, followed by the [*] key. The format is HHMM.7. Press the [#] key to exit the User Program Mode.8.3.14 Option 41 - Edit the Date[*] [MASTER CODE] [*] [4] [1] [*] [DATE] [*] [#]1. Enter the User Program Mode as per steps 1 - 4 of section 8.2.2. The LCD display reads „Option Menu‟, „Add User Code‟.3. To select menu option 41 – „Edit Date‟, press the [4] [1] keys followed by the [*] key oralternatively use the [PANIC] or [MED] keys to scroll through the list of programmable optionsuntil you reach the option you want.4. Press the [*] key.5. The LCD display reads „New Date?‟6. Enter the [DATE] that you wish to edit, followed by the [*] key. The format is DDMMYY.7. Press the [#] key to exit the User Program Mode.9. Stay ZonesStay zones are those zones that are bypassed automatically when the system is "STAY ARMED". To avoidtriggering the alarm, zones such as bedrooms that are protected by Passive Infra-Red (PIR) detectors orwindows that may be opened, must be bypassed when "staying at home". Stay zones need only beprogrammed once. Each time the system is armed in the Stay Mode the pre-selected stay zones will bebypassed automatically. The panel allows for four unique STAY PROFILES to be stored. A STAY PROFILEstores a preselected combination of STAY and BUZZ zones to suit a specific STAY ARM requirement. If apartition is stay armed using Profile 1, it is possible to toggle the panel arm status directly to stay arm