Contents - Table Of Contents
- DESCRIZIONE
- MENU PRINCIPALE
- NAVIGAZIONE FRA LE PAGINE DISPLAY
- IMPOSTAZIONE FATTORE DI POTENZA DESIDERATO
- PAGINA FORME D'ONDA
- INGRESSI, USCITE, VARIABILI INTERNE, CONTATORI, INGRESSI ANALOGICI
- SOGLIE LIMITE (LIMX)
- ALLARMI UTENTE (UAX)
- PORTA DI PROGRAMMAZIONE IR
- IMPOSTAZIONE PARAMETRI DA PC
- TABELLA DEI PARAMETRI
- ALLARMI
- TABELLA FUNZIONI INGRESSI
- TABELLA MISURE PER LIMITI / USCITE ANALOGICHE
- MENU COMANDI
- PROCEDURA RESET ALLARME A20
- DESCRIPTION
- MAIN MENU
- DISPLAY PAGE NAVIGATION
- TARGET POWER FACTOR SET-UP
- WAVEFORM
- INPUTS, OUTPUTS, INTERNAL VARIABLES, COUNTERS, ANALOG INPUTS
- LIMIT THRESHOLDS (LIMX)
- MASTER-SLAVE CONFIGURATION
- IR PROGRAMMING PORT
- PARAMETER SETTING (SETUP) WITH PC
- PARAMETER TABLE
- ALARMS
- INPUT FUNCTION TABLE
- OUTPUT FUNCTION TABLE
- COMMANDS MENU
- A20 ALARM RESET PROCEDURE
- MENU PRINCIPAL
- NAVIGATION ENTRE LES PAGES DE L'AFFICHEUR
- PARAMETRAGE DU FACTEUR DE PUISSANCE OBJECTIF
- ENTREES, SORTIES, VARIABLES INTERNES, COMPTEURS, ENTREES ANALOGIQUES
- VARIABLES A DISTANCE (REMX)
- PORT DE PROGRAMMATION IR
- TABLEAU DES PARAMETRES
- ALARMES
|
ICAR PQS rev8 may1829 / 86The controller displays the imminent connection or disconnection of the steps with the flashing of their identification number(above). The flashing can last in cases in which the insertion of a step is not possible due to the reconnection time (discharge timeof the capacitor). If the number above step is light gray, it means that the step is not available because its reconnection time is notyet expired. The device then waits for the end of the reconnection time.4.3 TEST ModeThe activation and deactivation of the outputs is done as for the manual mode, but without considering the reconnection time.Once in programming and parameters are set, the unit will automatically exit the test mode.If you need to enter TEST mode use the appropriate command in the Command menu.5 MAIN MENUThe main menu is made up of a group of graphic icons (shortcuts) that allow rapid access to measurements and settings.Starting from normal viewing, press key. The main menu screen is displayed. Press ▲▼ to rotate clockwise/counter clockwiseto select the required function. The selected icon is highlighted and the central part of the display shows the description of thefunction. Press to activate the selected function.If some functions are not available, the correspondent icon will be disabled, that is shown in a light grey colour.etc. - Shortcuts that allow jumping to the first page of that group. Starting from that page it is still possible to moveforward-backward in the usual way.- Switch the operation to manual or automatic mode.–Opens the password entry page, where it is possible to specify the numeric codes that unlock protected functions (parametersetting, commands menu).– Access point to the setup menu for parameter programming. See dedicated chapter.– Access point to the commands menu, where the authorised user can execute some clearing-restoring actions.6 PASSWORD ACCESSThe password is used to enable or lock the access to setting menu (setup) and to commands menu. For brand-new devices (factorydefault), the password management is disabled and the access is free. If instead the passwords have been enabled and defined,then to get access, it is necessary to enter the password first, specifying the numeric code through the keypad. To enable passwordmanagement and to define numeric codes, see setup menu M15 Password. There are two access levels, depending on the codeentered: User-Level access (Usr) – Allows clearing of some recorded values and the editing of a restricted number of setupparameters. Advanced access level (Adv) – Same rights of the user access plus full settings editing-restoring.From normal viewing, press to recall main menu, select the password icon and press .(fig..1) The display shows the screenin picture (fig.2): Keys ▲and ▼change the selected digit (fig.3) Keys ◄ and ► move through the digits (fig.4)Enter all the digits of the numeric code, then move on the key icon. If the password code entered matches the User access code(password:1000) or the Advanced access code (password:2000 Available value only if the controller is not installed on the ICARcabinet) , then the correspondent unlock message is shown. Once unlocked the password, the access rights last until: the device is powered off. the device is reset (after quitting the setup menu). the timeout period of two minutes elapses without any keystroke.To quit the password entry screen press key.fig.1 fig.2 fig.3 fig.4Switches toautomatic modeVoltage – currentpageEvent logPower pageStep lifestatisticsharmonicsSystem info pageSetup menuComandsPasswordentryMain page Switches tomanual mode