Contents - Table Of Contents
- DESCRIZIONE
- MENU PRINCIPALE
- NAVIGAZIONE FRA LE PAGINE DISPLAY
- IMPOSTAZIONE FATTORE DI POTENZA DESIDERATO
- PAGINA FORME D'ONDA
- INGRESSI, USCITE, VARIABILI INTERNE, CONTATORI, INGRESSI ANALOGICI
- SOGLIE LIMITE (LIMX)
- ALLARMI UTENTE (UAX)
- PORTA DI PROGRAMMAZIONE IR
- IMPOSTAZIONE PARAMETRI DA PC
- TABELLA DEI PARAMETRI
- ALLARMI
- TABELLA FUNZIONI INGRESSI
- TABELLA MISURE PER LIMITI / USCITE ANALOGICHE
- MENU COMANDI
- PROCEDURA RESET ALLARME A20
- DESCRIPTION
- MAIN MENU
- DISPLAY PAGE NAVIGATION
- TARGET POWER FACTOR SET-UP
- WAVEFORM
- INPUTS, OUTPUTS, INTERNAL VARIABLES, COUNTERS, ANALOG INPUTS
- LIMIT THRESHOLDS (LIMX)
- MASTER-SLAVE CONFIGURATION
- IR PROGRAMMING PORT
- PARAMETER SETTING (SETUP) WITH PC
- PARAMETER TABLE
- ALARMS
- INPUT FUNCTION TABLE
- OUTPUT FUNCTION TABLE
- COMMANDS MENU
- A20 ALARM RESET PROCEDURE
- MENU PRINCIPAL
- NAVIGATION ENTRE LES PAGES DE L'AFFICHEUR
- PARAMETRAGE DU FACTEUR DE PUISSANCE OBJECTIF
- ENTREES, SORTIES, VARIABLES INTERNES, COMPTEURS, ENTREES ANALOGIQUES
- VARIABLES A DISTANCE (REMX)
- PORT DE PROGRAMMATION IR
- TABLEAU DES PARAMETRES
- ALARMES
|
ICAR PQS rev8 may1837 / 8618 PARAMETER SETTING (SETUP) WITH PCYou can use the PFC Remote Monitoring software to transfer (previously programmed) set-up parameters from the power factorreally to the hard drive of the PC and vice versa. The parameter may be partially transferred from the PC to the power factorcontroller, transferring only the parameters of the specified menus.The PC can be used to set parameters and also the following:o Info page where you can enter application information, characteristics, data, etc.19 PARAMETER SETTING (SETUP) FROM FRONT PANELTo open the parameters programming menu (setup): turn the power factor controller in MAN mode and disconnect all the steps in normal measurements view, press to call up the main menu select the icon . If it is disabled (displayed in grey) you must enter the password (see chapter 7. Password access). press to open the setup menu.The table shown in the illustration is displayed, with the settings sub-menus of all the parameters on the basis of their function.Select the required menu with keys ▲▼and confirm with .Press ◄ to return to the values view.Settings: menu selectionThe following table lists the available submenus:Cod MENU DESCRIPTIONM01 UTILITY Language, brightness, display pages etc.M02 GENERAL Panel/plant dataM03 STEP Capacitor step configurationM04 MASTER OUTPUTS Programmable outputs of master deviceM05 MASTER / SLAVE Device role (master or slave)M06 SLAVE 01 OUTPUTS Programmable outputs of slave device 01… …M13 SLAVE 08 OUTPUTS Programmable outputs of slave device 08M14 PROG. INPUTS Programmable digital inputsM15 PASSWORD Password access managementM16 COMMUNICATION Communication channels parametersM17 BASE PROTECTIONS Base protections of the panelM18 HARMONIC PROT. Harmonic protections (MCP5 module)M19 MISCELLANEOUS Various settingsM20 LIMIT THRESHOLDS Limit thresholds on measurementsM21 COUNTERS Generic programmable countersM22 ANALOG INPUTS Programmable analog inputsM23 ANALOG OUTPUTS Programmable analog outputsM24 ENERGY PULSES Pulses for energy meters incrementM25 USER ALARMS Programmable user alarmsM26 ALARM PROPERTIES Action caused by alarmsSelect the sub-menu and press to show the parameters. Each parameter is shown with code, description and actualsetting value.Set-up: parameter selectionTo modify the setting of one parameter, select it and then press . If the Advanced level access code has not been entered, itwill not be possible to enter editing page and an access denied message will be shown. If instead the access rights are confirmed,then the editing screen will be shown.ParametercodeParameterdescriptionPresent settingvalueSelectedparameter
PreviousNext |