Contents - Table Of Contents
- DESCRIZIONE
- MENU PRINCIPALE
- NAVIGAZIONE FRA LE PAGINE DISPLAY
- IMPOSTAZIONE FATTORE DI POTENZA DESIDERATO
- PAGINA FORME D'ONDA
- INGRESSI, USCITE, VARIABILI INTERNE, CONTATORI, INGRESSI ANALOGICI
- SOGLIE LIMITE (LIMX)
- ALLARMI UTENTE (UAX)
- PORTA DI PROGRAMMAZIONE IR
- IMPOSTAZIONE PARAMETRI DA PC
- TABELLA DEI PARAMETRI
- ALLARMI
- TABELLA FUNZIONI INGRESSI
- TABELLA MISURE PER LIMITI / USCITE ANALOGICHE
- MENU COMANDI
- PROCEDURA RESET ALLARME A20
- DESCRIPTION
- MAIN MENU
- DISPLAY PAGE NAVIGATION
- TARGET POWER FACTOR SET-UP
- WAVEFORM
- INPUTS, OUTPUTS, INTERNAL VARIABLES, COUNTERS, ANALOG INPUTS
- LIMIT THRESHOLDS (LIMX)
- MASTER-SLAVE CONFIGURATION
- IR PROGRAMMING PORT
- PARAMETER SETTING (SETUP) WITH PC
- PARAMETER TABLE
- ALARMS
- INPUT FUNCTION TABLE
- OUTPUT FUNCTION TABLE
- COMMANDS MENU
- A20 ALARM RESET PROCEDURE
- MENU PRINCIPAL
- NAVIGATION ENTRE LES PAGES DE L'AFFICHEUR
- PARAMETRAGE DU FACTEUR DE PUISSANCE OBJECTIF
- ENTREES, SORTIES, VARIABLES INTERNES, COMPTEURS, ENTREES ANALOGIQUES
- VARIABLES A DISTANCE (REMX)
- PORT DE PROGRAMMATION IR
- TABLEAU DES PARAMETRES
- ALARMES
|
ICAR PQS rev8 may1833 / 86NOTE: To remove a module, disconnect any dangerous voltage and repeat the operations from step 5 to step 2 in reverse. Pressin the point indicated with to release the module and remove it ().When the 8BGA power factor controller is powered on, it automatically recognises the modules that have been mounted.If the system configuration has changed with respect to the last saved, (one module has been added or removed), the base unitasks the user to confirm the new configuration. In case of confirmation, the new configuration will be saved and will becomeeffective, otherwise the mismatch will be shown at every subsequent power-on of the system.The present system configuration is shown in the dedicated page of the display (expansion modules), where it is possible to seethe number, the type and the status of the modules. The I/O numbering is shown under each module.The status (energised/de-energised) of every single I/O and communication channel is highlighted in reverse11.1 Additional resourcesThe expansion modules provide additional resources that can be used through the dedicated setup menus.The setup menus related to the expansions are always accessible, even if the expansion modules are not physically fitted.Since it is possible to add more than one module of the same typology (for instance two communication interfaces), the setupmenus are multiple, identified by a sequential number.The following table indicates how many modules of each group can be mounted at the same time. The total number of modulesmust be less or equal than 4.MODULE TYPE CODE FUNCTION MAX Nr.ADDITIONAL STEPS OUT 2NO 2 RELAY STEPS 4STR 4NO 4 STATIC STEPS (FAST) 2COMMUNICATIONCOM USB USB 2COM 232 RS-232 2COM 485 RS-485 2WEB ETH Ethernet 1COM PRO Profibus® DP 1COM GSM GSM-GPRS 1DIGITAL I/O INP 4OC 4 INPUTS 22IN 2SO 2 INPUTS + 2 ST. OUTPUTS 4ANALOG I/OINP 2AN 2 ANALOG INPUTS 2OUT 2AN 2 ANALOG OUTPUTS 2MCP5 CAPACITOR HARMONIC PROTECTION 411.2 CommunicationThe 8BGA power factor controller supports a maximum of 2 communication modules, indicated as COMn. The communicationsetup menu is thus divided into two sections (n=1 … 2) of parameters for the setting of the ports.The communication channels are completely independent, both for the hardware (physical interface) and for the communicationprotocol.The two channels can communicate at the same time.Activating the Gateway function it is possible to use a 8BGA power factor controller with both an Ethernet port and a RS485 port,that acts as a bridge over other power factor regulators equipped with RS-485 only, in order to achieve a more economicconfiguration (only one Ethernet port).In this network, the power factor controller with Ethernet port will be set with both communication channels (two among COM1,COM2) with Gateway function set to ON, while the other power factor relays will be configured normally with Gateway = OFF.12 INPUTS, OUTPUTS, INTERNAL VARIABLES, COUNTERS, ANALOG INPUTSThe inputs and outputs are identified by a code and a sequence number. For instance, the digital inputs are identified by codeINPx, where x is the number of the input. In the same way, digital outputs are identified by code OUTx.The sequence number of I/Os is simply based on their mounting position, with a progressive numbering from left to right.It is possible to manage up to 4 analog inputs (AINx), connected to external analog sensors (temperature, pressure, flow etc). Thevalue read from the sensors can be scaled to any unit of measure, visualized on the display and transmitted on the communicationbus. The value read from analog inputs is shown on the dedicated display page. They can be used to drive LIMx limit thresholds,that can be linked to an internal or external output.The expansion I/O numbering starts from the last I/O installed on the base unit. For example, with OUT1…OUT8 digital outputson the base unit, the first digital output on the expansion modules will be OUT9. See the following table for the I/O numbering:Number and state of additionalresources In reverse = activeType of expansion module