Contents - Table Of Contents
- DESCRIZIONE
- MENU PRINCIPALE
- NAVIGAZIONE FRA LE PAGINE DISPLAY
- IMPOSTAZIONE FATTORE DI POTENZA DESIDERATO
- PAGINA FORME D'ONDA
- INGRESSI, USCITE, VARIABILI INTERNE, CONTATORI, INGRESSI ANALOGICI
- SOGLIE LIMITE (LIMX)
- ALLARMI UTENTE (UAX)
- PORTA DI PROGRAMMAZIONE IR
- IMPOSTAZIONE PARAMETRI DA PC
- TABELLA DEI PARAMETRI
- ALLARMI
- TABELLA FUNZIONI INGRESSI
- TABELLA MISURE PER LIMITI / USCITE ANALOGICHE
- MENU COMANDI
- PROCEDURA RESET ALLARME A20
- DESCRIPTION
- MAIN MENU
- DISPLAY PAGE NAVIGATION
- TARGET POWER FACTOR SET-UP
- WAVEFORM
- INPUTS, OUTPUTS, INTERNAL VARIABLES, COUNTERS, ANALOG INPUTS
- LIMIT THRESHOLDS (LIMX)
- MASTER-SLAVE CONFIGURATION
- IR PROGRAMMING PORT
- PARAMETER SETTING (SETUP) WITH PC
- PARAMETER TABLE
- ALARMS
- INPUT FUNCTION TABLE
- OUTPUT FUNCTION TABLE
- COMMANDS MENU
- A20 ALARM RESET PROCEDURE
- MENU PRINCIPAL
- NAVIGATION ENTRE LES PAGES DE L'AFFICHEUR
- PARAMETRAGE DU FACTEUR DE PUISSANCE OBJECTIF
- ENTREES, SORTIES, VARIABLES INTERNES, COMPTEURS, ENTREES ANALOGIQUES
- VARIABLES A DISTANCE (REMX)
- PORT DE PROGRAMMATION IR
- TABLEAU DES PARAMETRES
- ALARMES
|
ICAR PQS rev8 may1847 / 8621.2 Alarm propertiesVarious properties can be assigned to each alarm, including user alarms (User Alarms, UAx): Alarm enabled - General enabling of the alarm. If the alarm isn't enabled, it's as if it doesn't exist. Retained alarm - Remains in the memory even if the cause of the alarm has been eliminated. Operating mode – Operating modes where the alarm is enabled. Global alarm 1 -2 -3 - Activates the output assigned to this function. Step disconnection mode – Defines whether and how the capacitor steps must be disconnected when the alarm is present.OFF = no disconnection, SLOW = gradual disconnection, FAST = Immediate disconnection. Slave disconnection mode – Defines, for Master-Slave applications, if when this alarm arises, the disconnection isextended to all the step of the system (GENERAL) or only to the output of the interested panel (LOCAL). Inhibition - The alarm can be temporarily disabled by activating an input that can be programmed with the Inhibit function. Modem call – The alarm will be signalled remotely by sending a modem call under the conditions and modality defined inmodem parameters. No LCD - The alarm is managed normally, but not shown on the display. Delay time – Time delay in minutes or seconds before the alarm is generated.21.3 Alarm properties tableCODDEFAULT ALARM PROPERTIESenableretentiveonly in aut modeglobal alram 1global alarm 2global alarm 3sted disconnectionmodeslave disconnectionmodeinhibitionmodemno lcddelay timeminsecA01 ON OFF A/M GLB1 OFF OFF OFF GEN OFF OFF OFF 15 ●A02 OFF OFF AUT GLB1 OFF OFF OFF GEN OFF OFF OFF 5 ●A03 ON OFF AUT GLB1 OFF OFF IMM GEN OFF OFF OFF 30 ●A04 ON OFF A/M GLB1 OFF OFF OFF GEN OFF OFF OFF 60 ●A05 ON OFF AUT GLB1 OFF OFF IMM GEN OFF OFF OFF 60 ●A06 ON OFF AUT GLB1 OFF OFF IMM GEN OFF OFF OFF 15 ●A07 ON RIT AUT GLB1 OFF OFF IMM LOC OFF OFF OFF 60 ●A08 ON OFF AUT GLB1 OFF OFF SLOW GEN OFF OFF OFF 3 ●A09 ON OFF AUT GLB1 OFF OFF IMM GEN OFF OFF OFF OFFA10 NOT USEDA11 ON OFF A/M GLB1 OFF OFF IMM LOC OFF OFF OFF 3 ●A12 ON OFF A/M GLB1 OFF OFF SLOW LOC OFF OFF OFF 3 ●A13 OFF OFF A/M GLB1 OFF OFF IMM LOC OFF OFF OFF 3 ●A14 OFF OFF A/M GLB1 OFF OFF IMM LOC OFF OFF OFF 3 ●A15 OFF OFF A/M GLB1 OFF OFF IMM LOC OFF OFF OFF 3 ●A16 OFF OFF A/M GLB1 OFF OFF IMM LOC OFF OFF OFF 3 ●A17 OFF RIT A/M GLB1 OFF OFF IMM LOC OFF OFF OFF 60 ●A18 OFF RIT AUT GLB1 OFF OFF IMM LOC OFF OFF OFF 60 ●A19 ON RIT AUT GLB1 OFF OFF IMM GEN OFF OFF OFF 30 ●A20 ON RIT A/M GLB1 OFF OFF OFF OFF OFF OFF OFF OFFA21 ON RIT A/M GLB1 OFF OFF OFF OFF OFF OFF OFF OFFA22 ON RIT A/M GLB1 OFF OFF OFF OFF OFF OFF OFF OFFA23 OFF OFF A/M GLB1 OFF OFF OFF GEN OFF MDM OFF OFFUAx OFF OFF A/M OFF OFF OFF OFF GEN OFF OFF OFF OFF22 INPUT FUNCTION TABLEThe following table shows all the functions that can be attributed to the INPn programmable digital inputs.Each input can be set for an reverse function (NA - NC), delayed energizing or de-energizing at independently set times.Some functions require another numeric parameter, defined in the index (x) specified by parameter P14.n.02.See menu M14 Programmable inputs for more details.FUNCITON DESCRIPTIONOFF Disabled inputConfigurable Free user configurable input INPx. Used for instance to generate a user alarm UA or to count on a CNT counter.Automatic mode When active, switches system to AUT modeManual mode When active, switches system to MAN modeSelect cosphi setpoint x When active, selects the cosphi setpoint x (x=1…3).Keyboard lock Locks front keyboard.Settings lock Locks access to setup menu and command menu.Alarm Inhibition Selectively disables alarms that have inhibit property set to ON.