709DATA OPERATION9 Low-speed data communicationIn addition to the data communication, a low-speed data com-munication capability is available.Low-speed data communications require narrow passbandwidth, thus digital voice mode is used and provides a simul-taneous operation with voice and data.q Set the desired frequency.w Select DV (Digital voice) mode.• Click [MODE] on the main screen or push [MODE] on the RC-24.eSet another settings, such as repeater, digital codesquelch, transmit output power.rClick “ ” or select “Exit(X)” in File menu to quit the appli-cation.NOTE: The application must be quit during low-speed dataoperation. The application and a low-speed data commu-nication software cannot be operated simultaneously, dueto both of data passing through the ID-1 USB port.t Start up the low-speed data communication application.ySet the application as follows.• Port : The same COM port number as ID-1’s• Baud rate : 19200 bps• Data : 8 bit• Parity : None• Stop : 1 bit• Flow control : Xon/XoffuPush and hold [PTT] to transmit, release to receive thedata.• Refer to the instruction of the application that how to send or re-ceive data.NOTE:• A communication error may occur depending on the com-bination of the OS used, and the low-speed data commu-nication application installed in your PC.• “Packet-loss” (loosing a part of data) may occur whencommunicating through internet network. When “Packet-loss” occurs, [TX/RX] indicator lights orange.• ASCII code’s characters are only usable.