Jenn-Air JBR2086HES Use & Care Manual
(SELECT NIODELS)System Specification and Performance Data SheetRefrigerator Water FHter Cartridge Mode U KF8001A××SpecificationsService Flow Rate (Maximum) .............................................0.78 GPM (2.9 L/rain)Rated Service Life UKF8001AXX-750 (Maximum) ......750 gallons/2838 litersMaximum Operating Temperature .....................................100 ° F/38 ° CMinimum Pressure Requirement ........................................35 psi!241 kPAMinimum Operating Temperature ......................................33 ° F/1 ° CMaximum Operating Pressure .............................................120 psi/827 kPA1000 Apollo RoadEagan, Minnesota 55121-2240651.450.4913EPA EST #35917-MN-1Performance DataParameterChlorineT&OParticulate _*100834/BUSEPAMCLStandard No. 42: Aesthetic EffectsInfluentChallenge Concentration2.0 mg/L ± 10%at least 10,000 particles/mlInfluentAverage1.88 mg/L5300,000 #/mlEffluentAverage Maximum<0.05130304 mg/L 0.08 mg/L30,583 #/ml 69.000 #/ml% ReductionAverage Minimum>9726% 96.84%99.52% 98.94%Min. Require(_Reduction50%85%ParameterTurbidityCystsAsbestosLead at pH 6.5Lead at pH 8.5Mercury at pH 6.5Mercury at pH 8.5AtrazineBenzeneCarbofuranp-DichlolobenzeneLindaneToxapheneUSEPAMCL1 NTU**99.5% Reduction99% Reduction0.015 mg/L0.015 mg/L0.002 mg/L0.002 mg/L0.003 m_)/L0.005 m_/L0.04 mq/L0.075 mg/L0.0002 m_)/L0.003 mg/LStandard No. 53: Health EffectsInfluent Influent EffluentAverage9709%>99.99%>99.99%>99.35%>99.33%95.70%86.22%76.99%95.71%98.74%99.76%98.72o/o92.97o/oChallenge Concentration11 ± 1 NTU***Minimum 5O,000/L10_ 10_fibers/L; fibers >10 micrometers in length0.15 mg/L + 10%0.15 mg/L + 10%.006 mg/L ± 10%.006 mg/L ± 10%0.009 m_)/L + 10%0.015 m g/L ± 10%0.08 mq/L ± 10%.225 mg/L ± 10%0.002 m_)/L + 10%0.015 ± 10%Average10.7 NTU166500 #/L155 MF/L0.153 mg/L0.150 mg/L0.006 mg/L0.006 mg/L0.009 m_)/L0.014 m_/L0.081 mg/L0.208 mq/L0.002 m_)/L0.015 mg/LAverage Maximum0.31 NTU .049 NTU #/L <1 #/L MF/L MF/L<.001 mg/L <.001 mg/L<.001 mg/L <.001 mg/L0.0003 mg/L 0.0005 mg/L0.0008 mg/L 0.0015 mg/L<0.002 mg/L 0.002 mg/L0.0006 m q/L 0.0011 m_iL<0.001 m g/L <0.001 mg/L<0.0005 m g/L <0.0005 mq/L0.0O0 m_)/L <0.0001 mg/L<0.001 mg/L <0.001 mg/L% ReductionMinimum95.20%>99.99%>99.99%>9929%>9929%90.91%75.93%75.31%92.14%98.46%99.74%96.50%91.67%* Tested using a flow rate of 0.78 gpm; pressure of 60 psig; pH of Z5 + 0.5; temp. ofMin. Require_Reduction0.5 NTU>99.95%99%0.10 mg/L0.10 mg/L0.002 mg/L0.002 mg/L0.003 m_)/L0.005 m_/L0.04 mf_/L0.075 mg/L0.0002 m_)/L0.003 mg/L68 ° + 5° F (20 ° + 3° C)** Measurement in Particles/ml. Particles used were 0.5 - 1 microns*** NTU - Nephelometric Turbidity UnitsTested and certified by NSF International against ANSI/NSF Standards 42 & 53in models UKF8001AXX-750 for the reduction of:Standard No. 42: Aesthetic Effects Standard No. 53: Health EffectsTaste and OdoT Reduction Cbenlical Reduction UnitChlorine Taste & Odor Lead, Atrazine, Lindane. Benzene,Mechanical Filtration Unit Carbofuran, p-Dichlorobenzene, MercuryParticulate Reduction Class 1 & Toxaphene ReductionMechanical Filtration UnitCyst, Turbidity and Asbestos ReductionGeneral Use ConditionsRead this Performance Data Sheet and compare thecapabilities of this unit with your actual water treatmentneeds.DO NOT use this product where water is microbiologic-ally unsafe or of unknown quality without adequatedisinfection before or after the system. System certifiedfor cyst reduction may be used on disinfected waterthat may contain filterable cysts.USE ONLY WITH COLD WATER SUPPLY. CHECK FORCOMPLIANCE WITH THE STATEAND LOCAL LAWSAND REGULATIONS.The PuriClean" II retractable water filtration system uses aUKF8001AXX replacement cartridge. Timely replacement offilter cartridge is essential for performance satisfaction fromthis filtration system. Please refer to the applicable section ofyour Use & Care Guide for general operation, maintenancerequirements and troubleshooting. Suggested retail price ofreplacement water filter is $39.99.This system has been tested according to ANSI/NSF 42 and53 for reduction of the substance listed above. Theconcentration of the indicated substances in water enteringthe system was reduced to a concentration less than or equalto the permissible limit for water leaving the system, asspecified in ANSI/NSF 42 and 53.14 |
Related manuals for Jenn-Air JBL2086HES
Jenn-Air jbr2086hes User & Care Manual
Jenn-Air JBL2088HES Use & Care Manual
Jenn-Air JSD2690HES Use & Care Manual
Jenn-Air JBC2088HTQ Use & Care Manual
Jenn-Air JUR24FE Use & Care Manual
Jenn-Air JFD2589KES Use & Care Manual
Jenn-Air JFC2089HEP Use & Care Manual
Jenn-Air JFC2089HPR Use & Care Manual
Jenn-Air JFC2089HPR Use & Care Manual
Jenn-Air JFC2089HEP Use & Care Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine