32 English 5.906-269.0 Rev. 00 (03/11)NoteModel 1:Reset of the red battery monitoring LED with a chargestatus of the battery of 25.8 V. You cannot continueuntil you do this.Model 2:This does not require a reset of the battery monitoringLED.When the battery is first connected to an appliance,charge it completely to reset a possible total dis-charge that may have been saved in the control.6.2.5 Indicator lamp - battery monitoringDischarge Operating mode, battery capacity in % Charging mode, charge statusin %Glows green continuously Battery charged, 40% - 100%, 23.0 V ± 0.2 V 80% - 100%, charge protectionactive, discharge level 1Glows yellow continuously Remaining capacity 20% - 40%, 22.3 V ± 0.2V60% - 80%, discharge level 2Slowly* blinks yellow - 40% - 60%Slowly * blinks yellow/red - 20% - 40%Slowly* blinks red Remaining capacity 0% - 20%, 21.0 V ± 0.2 VIf the indicator lamp "fault" also blinks slowly,there is a malfunction with the brush.0% - 20%, discharge level 3Glows red continuously Battery depleted (total discharge protection21.0 V ± 0.2 V)The suction turbine is switched off after atrailing time of 10 seconds.Battery depleted, total dischargeprotectionChargeBlinks red rapidly** If the indicator lamp for "fault" blinks rapidly,the battery is defective.Refresh chargeBlinks yellow rapidly** - Rapid charge, main chargeBlinks green rapidly** - The charge cannot be main-tained.Slowly* blinks green - The charge maintenance is per-formed.* Blink frequency slow = 1x per second** Blinking frequencyrapid= 4x per second