English 5.906-269.0 Rev. 00 (03/11) 536.8.6 Polishing (with vacuuming)Initial use DisplayBattery: E...FShutting downSwitch the programme selector switch (S2) to position “Polishing with vacuuming" Drive switch (S4) switched off Suction turbine (M2) active Cleanspeed active ("Cleanspeed Edit" set to "1" in setup menu) Suction turbine speed (M2) ("SUCTred Edit“ set to "1" in setup menu)DisplayBattery: E...F Red LED "Fault" is glowing continuous-ly After approx. 10 seconds of overload,the following will be shut off– Brush motor– Solenoid valve water– Dosing pump detergent (optional) DisplayBrush overload Red LED "Fault" is blinking Switch the key switch off and performstartupDrive and brush motor(M1 und M2) readyDeadman switch (S3)actuated?NoYesBrush motor (M1) activeYesYes Brush motor overload?NoDrive switch (S4)switched on?NoYesThe drive motor (M3)starts via the on rampand moves forward con-tinuously at 4 km/h.Continued on next page.