ITS-BA-e-072017CountingUser manual ME-Nr.:22017077 01/073 CountingThe terminal has additional functions for piece counting. The relevant settings in themenu are described in Section 4.4.1.3.1 Counting parts into a container1. Place the empty container on the scale and press .The container is tared and the zero display appears.2. Place 10 reference parts on the scale and press .-or-➜ Place the number of pieces displayed above the key on the scale and press.The scale determines the average piece weight and then shows the number ofpieces.3. Add more parts to the container until the required number of pieces is reached.Note • The average piece weight remains saved in the factory setting until a new averagepiece weight is determined.• With it is possible to switch between the number of pieces and the weighingunits preset.• When the number of pieces is displayed, it is possible to display with theaverage piece weight, i. e. the weight of a single reference part, for 2 seconds.• If A.CL-APW ON is set in the menu, the average piece weight is automaticallycleared after each counting operation. The average piece weight must be deter-mined again for the next counting operation.• If ACCurCY ON is set in the menu, the accuracy achieved is briefly shown afterthe number of pieces is determined.