4States of the LockFactory ModeThe factory mode is one of three primary states of the E-Plex Lock. The maincharacteristics of this state are:• The E-Plex Lock opens only when the 8-digit mastercombination (1-2-3-4-5-6-7-8) is keyed in.• The visual indication for ‘access granted’ is green LED flashing once.A high-pitched tone is also generated while the green LED is on.• The Master User must change the combination to be able to exit thefactory mode, and switch to the access mode.Access ModeThis mode refers to a lock that is operational for user access, and not in facto-ry or Programming Mode.Pushbutton Programming ModeThe E-Plex lock enters the Pushbutton Programming Mode when the userenters the master combination or one of the manager combinations, precededand followed by the character ‘#’ (ex: #12345678#). Once the E-Plex Lock is inthe Pushbutton Programming Mode, the Master/Manager can enter one or morecommand sequences. Each command sequence ends with a ‘#’ character thatacts like an < enter > character. At the very end of all sequences of program-ming commands, enter one more # to remove the lock from the PushbuttonProgramming Mode to return to normal access mode.Sequence of Operations for Start-Up ProgrammingWhat is the recommended sequence of operations?With the E-Plex Lock in the factory mode.• Program the Access Code Length (default length is four digits).The accesscode field length can only be changed when the lock is not activated(when still in the factory mode).• Change factory Master to your own Master Code (always eight digits) toplace lock in access mode.Put lock in Pushbutton Programming Mode.• Set the Date / Time• Program the Lock ID and Unlock time• Program the Lock for the Duration of Passage Mode (if desired)• Program the Lock for Tamper Time Settings• Program the Lock for Buzzer Volume• Add Access Codes as desired