1-46 (No.RA020)4.8 Common SectionItem Condition Measurement Adjustment Specifications/RemarksPanel tuningmodePC test mode Test-equip-mentUnit Ter-minalUnit Parts Method1.Setting1) DC voltage:13.6V2) SSG standard modulation[Wide] MOD:1kHz,DEV:3kHz[Narrow] MOD:1kHz,DEV:1.5kHz2.ReceiveAssist1) Adj item:[RAST]Adjust:[****]2) Adj item:[Low1 RAST]→[Low2 RAST]→[Low3 RAST]→[Center1 RAST]→[Center2 RAST]→[Center3 RAST]→[High1 RAST]→[High2 RAST]→[High3 RAST]Adjust:[****]Press [ ] keyto store the ad-justment val-ue.1) Adj item:[Receive Assist]2) Adj item:[Low1]→[Low2]→[Low3]→[Center1]→[Center2]→[Center3]→[High1]→[High2]→[High3]Press [Apply All] but-ton to store the ad-justment value.Panel [Paneltuningmode][],[][PCtestmode][←],[→][PC test mode][Automatic Adjust-ment]1) Press [Tune AssistVoltage] button.2) Press [Apply All] but-ton to store the adjust-ment value after theautomatic adjustmenthas finished.[Manual Adjustment][V] indicator on the PCwindow shows VCO lockvoltage. Change the ad-justment value to getVCO lock voltage withinthe limit of the specifiedvoltage.Note:Confirm the VCO lockvoltage approximately3 seconds after theadjustment value ischanged.2.5V±0.1V[Automatic Ad-justment]After the automaticadjustment is per-formed, verify thatthe VCO lock volt-age is within thevoltage rangewhich is specifiedby the manual ad-justment.[Manual Adjust-ment]Press [Apply All]button to store theadjustment valueafter all adjustmentpoint have beenadjusted.Note:The assist adjust-ment value mustbe between from340 to 3550.3.TransmitAssist1) Adj item:[TAST]Adjust:[****]2) Adj item:[Low1 TAST]→[Low2 TAST]→[Low3 TAST]→[Center1 TAST]→[Center2 TAST]→[Center3 TAST]→[High1 TAST]→[High2 TAST]→[High3 TAST]Adjust:[****]PTT: ONPress [ ] keyto store the ad-justment val-ue.1) Adj item:[Transmit Assist]2) Adj item:[Low1]→[Low2]→[Low3]→[Center1]→[Center2]→[Center3]→[High1]→[High2]→[High3]PTT: Press[Transmit] button.Press [Apply All] but-ton to store the ad-justment value.Panel [Paneltuningmode][],[][PCtestmode][←],[→][PC test mode][Automatic Adjust-ment]1) Press [Tune AssistVoltage] button.2) Press [Apply All] but-ton to store the adjust-ment value after theautomatic adjustmenthas finished.[Manual Adjustment][V] indicator on the PCwindow shows VCO lockvoltage. Change the ad-justment value to getVCO lock voltage withinthe limit of the specifiedvoltage.Note:Confirm the VCO lockvoltage approximately3 seconds after theadjustment value ischanged.2.5V±0.1V[Automatic Ad-justment]After the automaticadjustment is per-formed, verify thatthe VCO lock volt-age is within thevoltage rangewhich is specifiedby the manual ad-justment.[Manual Adjust-ment]Press [Apply All]button to store theadjustment valueafter all adjustmentpoint have beenadjusted.Note:The assist adjust-ment value mustbe between from340 to 3550.