NXR-71047ADJUSTMENTTransmitter SectionItem ConditionMeasurement AdjustmentSpecifications / RemarksTest-equipment Unit Terminal Unit Parts Method1. High Trans-mit PowerLimit AdjustFPU Test mode1) Adjust Item: [High TransmitPower Limit Adjust]Frequency: [Low], [Low’],[Center], [High’], [High]Press [Transmit] button.Power meter Rear TX ANT PCADJ53W±1.5W Press [Apply] button to storethe adjustment value.2. High Trans-mit PowerAdjustFPU Test mode1) Adjust Item: [High TransmitPower ]Frequency: [Low], [Low’],[Center], [High’], [High]Press [Transmit] button.50W±0.5W3. Low Trans-mit PowerLimit AdjustFPU Test mode1) Adjust Item: [Low TransmitPower Limit Adjust ]Frequency: [Low], [Low’],[Center], [High’], [High]Press [Transmit] button.28W±1.5W4. Low Trans-mit PowerAdjustFPU Test mode1) Adjust Item: [High TransmitPower Adjust ]Frequency: [Low], [Low’],[Center], [High’], [High]Press [Transmit] button.25W±0.5W5. MaximumDeviationAdjust[NXDN Nar-row]FPU Test mode1) Adjust Item: [Maximum De-viation (NXDN Narrow)]PCADJWrite the value asfollowings (typicalvalue)[Maximum Deviation(NXDN Narrow)] =530Press [Apply] button to storethe adjustment value.6. MaximumDeviationAdjust[NXDN VeryNarrow]FPU Test mode1) Adjust Item: [Maximum De-viation (NXDN Very Narrow)]Write the value asfollowings (typicalvalue)[Maximum Deviation(NXDN Very Nar-row)] = 5307. MaximumDeviationAdjust[AnalogWide]FPU Test mode1) Adjust Item: [Maximum De-viation (Analog Wide)]Write the value asfollowings (typicalvalue)[Maximum Deviation(Analog Wide)] =5308. MaximumDeviationAdjust[Analog Nar-row]FPU Test mode1) Adjust Item: [Maximum De-viation (Analog Narrow)]Write the value asfollowings (typicalvalue)[Maximum Deviation(Analog Narrow)] =530