NXR-71049ADJUSTMENTItem ConditionMeasurement AdjustmentSpecifications / RemarksTest-equipment Unit Terminal Unit Parts Method11. TD Devia-tion adjust[AnalogWide]FPU Test mode1) Adjust Item: [TD Deviation(Analog Wide)]Connect the Deviation Meterto the TX ANT end via the ATT.Deviation Meter settingLPF: 3kHz, HPF: OFFDe-emphasis: OFF2) Connect the AG to the TDTerminal of Control I/O Jack.AG Frequency: 100Hz (Sine Wave)AG Output level: 0.5Vpp (177mVrms)Press [Transmit] button.DeviationmeterOscilloscopeAGAF VTVMRear TX ANTControlI/O JackTD (PinNo.8)PCADJ0.75kHz Deviation ±0.1kHzPress [Apply] button to storethe adjustment value.12. TD Devia-tion adjust[Analog Nar-row]FPU Test mode1) Adjust Item: [TD Deviation(Analog Narrow)]Connect the Deviation Meterto the TX ANT end via the ATT.Deviation Meter settingLPF: 3kHz, HPF: OFFDe-emphasis: OFF2) Connect the AG to the TDTerminal of Control I/O Jack.AG Frequency: 100Hz (Sine Wave)AG Output level: 0.5Vpp (177mVrms)Press [Transmit] button.13. TransmitAudio Input(TA) adjust[AnalogWide]FPU Test mode1) Adjust Item: [Transmit AudioInput (TA) (Analog Wide)]Connect the Deviation Meterto the TX ANT end via the ATT.Deviation Meter settingLPF: 15kHz, HPF: OFFDe-emphasis: OFF2) Connect the AG to the TATerminal of Control I/O Jack.AG Frequency: 1kHz (Sine Wave)AG Output level: 280mVrmsPress [Transmit] button.DeviationmeterOscilloscopeAGAF VTVMRear TX ANTControlI/O JackTA (PinNo.9)PCADJ3.0kHz Deviation ±0.1kHzPress [Apply] button to storethe adjustment value.14. TransmitAudio Input(TA) adjust[Analog Nar-row]FPU Test mode1) Adjust Item: [Transmit AudioInput (TA) (Analog Narrow)]Connect the Deviation Meterto the TX ANT end via the ATT.Deviation Meter settingLPF: 15kHz, HPF: OFFDe-emphasis: OFF2) Connect the AG to the TATerminal of Control I/O Jack.AG Frequency: 1kHz (Sine Wave)AG Output level: 280mVrmsPress [Transmit] button.1.5kHz Deviation ±0.05kHzPress [Apply] button to storethe adjustment value.