TK-5210521. AF level [Panel test mode] SSG Panel ANT Panel Volume Turn the Volume 0.63V±0.1VSetting 1) CH-Sig:1-1 DVM Universal Knob Knob to obtainSSG output:-47dBm(1mV) AF VTVM connector 0.63V AF output.(MOD:1kHz/±3kHz) Dummy load2. Sensitivity 1) CH-Sig:1-1 SSG Check 12dB SINAD or moreCheck SSG output:-118dBm(0.28μV) AF VTVM•Wide (MOD:1kHz/±3kHz) Oscilloscope(Concentric SW:A) 2) CH-Sig:2-13) CH-Sig:3-1•Narrow 4) CH-Sig:1-1(Concentric SW:B) SSG output:-118dBm(0.28μV)(MOD:1kHz/±1.5kHz)5) CH-Sig:2-16) CH-Sig:3-13. RSSI [Panel tuning mode] Panel After inputreference 1) Adj item:[RSSI(Ref)] signal from SSG,adjust Adjust:[***] press [B] key.2) Adj item:[L RSSI(Ref)]t That numeric[C RSSI(Ref)]t[H RSSI(Ref)] will be storedAdjust:[***] in memory.SSG output:12dB SINAD level -3dB(MOD:1kHz/±3kHz)4. Squelch 1) Adj item:[W Squelch(1)] After input After adjusting SQL,(Threshold) Adjust:[***] signal from SSG, check SQL open/close.adjust 2) Adj item:[WL Squelch(1)]t press [B] key. [Panel test mode]•Wide [WC Squelch(1)]t[WH Squelch(1)] That numeric 1) CH-Sig:1-1(Concentric SW:A) Adjust:[***] will be stored SSG 12dB SINAD levelSSG output:12dB SINAD level -3dB in memory. -1.5dB:Open(MOD:1kHz/±3kHz) SSG -130dBm(0.07μV):Close2) CH-Sig:2-1SSG 12dB SINAD level-1.5dB:OpenSSG -130dBm(0.07μV):Close3) CH-Sig:3-1SSG 12dB SINAD level-1.5dB:OpenSSG -130dBm(0.07μV):Close•Narrow 3) Adj item:[N Squelch(1)] After adjusting SQL,(Concentric SW:B, C) Adjust:[***] check SQL open/Close.SSG output:12dB SINAD level -4dB [Panel test mode](MOD:1kHz/±1.5kHz) 1) CH-Sig:1-1SSG 12dB SINAD level-1.5dB:OpenSSG -130dBm(0.07μV):Close2) CH-Sig:2-1SSG 12dB SINAD level-1.5dB:OpenSSG -130dBm(0.07μV):Close3) CH-Sig:3-1SSG 12dB SINAD level-1.5dB:OpenSSG -130dBm(0.07μV):CloseADJUSTMENTMeasurement AdjustmentItem Condition Test- Unit Terminal Unit Parts Method Specifications/RemarksequipmentReceiver Section