– 31 –PC CONTROLCOMMAND REFERENCE GUIDEFA VFO A Frequency Parameters:P1 (Frequency)11 digits in Hz Blank digits must be entered as “0”.• The frequency set with this command is the frequency beforeRIT/XIT is added.Set1 2 3 4 5 6 7 8 9 10F A P1 P1 P1 P1 P1 P1 P1 P111 12 13 14 15 16 17 18 19 20P1 P1 P1 ;Read1 2 3 4 5 6 7 8 9 10F A ;Answer1 2 3 4 5 6 7 8 9 10F A P1 P1 P1 P1 P1 P1 P1 P111 12 13 14 15 16 17 18 19 20P1 P1 P1 ;FB VFO B Frequency Parameters:P1 (Frequency)11 digits in Hz Blank digits must be entered as “0”.• The frequency set with this command is the frequency beforeRIT/XIT is added.Set1 2 3 4 5 6 7 8 9 10F B P1 P1 P1 P1 P1 P1 P1 P111 12 13 14 15 16 17 18 19 20P1 P1 P1 ;Read1 2 3 4 5 6 7 8 9 10F B ;Answer1 2 3 4 5 6 7 8 9 10F B P1 P1 P1 P1 P1 P1 P1 P111 12 13 14 15 16 17 18 19 20P1 P1 P1 ;FC Change the Frequency (Tuning Control) Parameters:P1 (Direction to change)0: Up1: DownP2 (Size to change)0: Normal frequency step size1: Double the frequency step size2: 5 times the frequency step size3: 10 times the frequency step size4: 50 times the frequency step size5: 100 times the frequency step sizeSet1 2 3 4 5 6 7 8 9 10F C P1 P2 ;FL0 Select the Receive Filter Parameters:P1 (RX filter selection)0: A1: B2: C You cannot select “C” when the menu [6-10] (RX FilterNumbers) is set to “2”.P2 (270 Hz Option)0: Not installed1: InstalledSet1 2 3 4 5 6 7 8 9 10F L 0 P1 ;Read1 2 3 4 5 6 7 8 9 10F L 0 P1 ;Answer1 2 3 4 5 6 7 8 9 10F L 0 P1 P2 ;