Upgrading Your System 4-25Installing an Internal Hard Disk Drive1. Power off the system and remove the left side panel as described earlier in this chapter.CAUTIONObserve static precautions. Use an antistatic wrist strap.2. Remove the 3.5-inch hard disk drive from its protective wrapper. Record the drive model andserial number in the equipment log.3. Set any drive jumpers or switches before you install the drive. See the documentation thatcomes with the device for jumper or switch information.CAUTIONIf a drive bezel is installed, it must be removed because it blocks the air flow aroundthe drive. If the drive comes with drive rails, do not use them. Remove any railsalready attached.4. Remove the three screws holding the 3.5-inch drive bay to the rear of the chassis.5. Disconnect the power and signal cables from any installed drives.6. Swing the drive bay out of the chassis.7. Slide the drive bay towards the top of the chassis until the tabs on the bay are free from thechassis. Remove the drive bay from the chassis and place it on an antistatic surface.1243Removing the Disk Drive Bay8. Slide the drive into the bay until the screw holes line up. It may be necessary to temporarilyloosen the mounting screws on the already installed drives to position the new drive. Securethe drive to the bay with the four supplied screws.9. Replace the 3.5-inch drive bay. Insert the tabs into their slots on the chassis. Slide the drive baytowards the bottom of the chassis until the tabs hit their stops.10. Connect the signal and power cables to the drives. All device power cables are labeled andmust be installed in specific locations as shown below: