Chapter 4 - Terminals and Optional EquipmentChapter 4 4 - 23SECTION 4-6EXTERNAL PAGING4.6.1 External Page (Figure 4-15)Two external page zone/door box circuits are provided by each 2PGDAD installed. Each Door Box/externalpage circuit provides a dry relay contact. The external page speakers provided by the 2PGDAD modules are 1-8 - the relays on the 2PGDAD modules are numbered 1-8. Refer to Paging, External in the Software Manualfor additional details.The 2PGDAD module can be used for talkback with External Page, as can a CO trunk port with the properexternal page equipment (ex: Valcom) - set Program 31-06-03 to “0” for talkback.4.6.2 Installing an External Page System1. Connecting to the 2PGDAD Module:Make sure the jumper in the 2PGDAD module for the channel is set correctly. (Refer to Figure 4-4JUMPER SETTINGS on page 4-5).2. If a line cord was not previously connected to the 2PGDAD, complete Steps 3-6. Otherwise, skip to Step7.3. Install a modular jack for each 2PGDAD module. For each module, run one-pair 24 AWG station cablefrom the cross-connect block to a modular jack. Ground the unused pair.4. Terminate the extension leads to GRN/RED of the modular jack. Terminate the unused leads to the jack.5. Install bridging clips as required.6. Plug a modular line cord from the mod jack to the CN1 connector on the 2PGDAD module.7. Connect the two-conductor station cable from the CN5 connectors within the 2PGDAD module to theexternal relay/external page.A 2PGDAD circuit used for External Paging cannot also be used for an analog DoorBox.