Chapter 6.0 Access Code Types6.0 Access Code TypesThe alarm system provides the following user access code types:Code Add User DeleteUserArm Disarm AccessCodesUser Func-tionsInstallerMaster All All Yes Yes Yes Yes NoUser No No Yes Yes No No NoSupervisor All butMasterAll butMasterYes Yes Yes Yes NoDuress No No Yes Yes No No NoOne-timeuserNo No Yes 1/day No No NoInstaller and Master code are system codes that can be changed but not deleted. The other codes areuser-defined and can be added or deleted as necessary. By default, access codes have the same par-tition and attribute programming as the code used to program them.Note: When using 8-digit access codes, the minimum number of variations are:l 2083333 for HS2016/HS2016-4l 1388888 for HS2032l 1052631 for HS2064/HS2128l 200000 for HS2064 El 100000 for HS2128 EAdditionally, there are no disallowed codes.MasterCodeBy default the master code can access all partitions and can perform any keypadfunction. This code can be used to program all access codes, including the super-visor and duress codes. The master code is code # [01].UserCodesThis type of access code is used to arm and disarm assigned partitions and canaccess the User Functions menu.SupervisorCodesUse when you want to allow additional users to manage Access Codes [*5] or UserFunctions [*6]. Supervisor codes created by the master code will have the sameattributes as the master code. Supervisor codes created by another supervisor codewill have the same attributes, except the supervisor attribute. Must be assignedmanually afterward. After creation, attributes can be changed for all supervisorcodes. For information on how to program a supervisor code see "Configuring addi-tional User Options".DuressCodesUse if forced to access your keypad under threat. Duress codes function the sameas user access codes, except they transmit a Duress Report to your monitoring sta-tion when used to perform any function on the system.Duress codes cannot be used to access Access Codes [*5], User Functions [*6] orInstaller [*8] menus. For information on how to program a Duress Code see "Con-figuring additional User Options".One TimeUser CodeUsed to grant someone one-time access to your home once per day, i.e., a cleaningperson or contractor. The ability to disarm the system is reset at midnight or whenthe one-time user code is keyed in by the master code user. For information on howto program a One Time User Code see "Configuring Additional User Options".- 13 -