W415-1710 / B / 08.17.18EN60finishingInstalling a mantel between this appliance andelectronics or other materials that may be sensitiveto heat, will reduce the effect of direct heat on them.Follow mantel height and depth instructions for properclearance information.A non-combustible mantel is considered a non-combustible protrusion, see “finishing” for protrusionrestrictions.Electronics, picture frames, decors, or other wall-mounted objects must be 6” below the air outletopening and 6” above the finishing flange.Dynamic Heat Control™ATop offinishingflangeBottom of theappliance12.4 minimum combustible mantel clearances25 11/16" (65.2cm)2" (5.1cm)2" (5.1cm)12" (30.5cm) maxMANTEL HEIGHTMANTEL DEPTHBottom offinishing flangeOptional hearthextension (nodepth restric-tion)• Risk of fire. Maintain all specified air space clearances to combustibles. Failure to comply with theseinstructions may cause a fire or cause the appliance to overheat. Ensure all clearances (i.e. back, side, top,vent, mantel, front, etc.) are clearly maintained.• When using paint or lacquer to finish the mantel, the paint or lacquer must be heat resistant to preventdiscolouration.• Installing a television or other electronics above the appliance may cause discolouration, melting, or damageto the electronics. Use clearances as guidelines and refer to your TV manufacturer’s instructions for furtherinformation.! WARNING6” min.6” min.CeilingAir outlet opening