2-24 | ni.comChapter 2 Basic FunctionsSpecifying CF01 to CF36, CF 41 to CF52 CONFIG SettingsNote Excludes CF00 (Reset panel settings) and CF40 (Resets or applies LANinterface settings).Complete the following steps to specify the CONFIG settings.1. Press CONFIG.The CONFIG key lights, and the SET key blinks. The ammeter displays the parameternumber—CF00. The voltmeter displays the corresponding setting—rSt.2. Press CONFIG or turn the CURRENT knob to select the number of the parameter that youwant to set.When you press CONFIG, the RMX programmable power supply switches between theparameter ranges in the following order.CF00 -->CF20 -->CF30 -->CF40 -->CF50 -->measured value displayWhen you turn the CURRENT knob, the RMX programmable power supply incrementsthrough the parameter numbers within the currently selected parameter range.Tip Press CONFIG or turn the CURRENT knob to switch between the parameternumbers. These two methods switch between the parameter numbers differently.3. Turn the VOLTAGE knob to change the value of the parameter.4. To specify or display other parameters, repeat steps 2 and 3. To stop specifying CONFIGsettings, proceed to step 5.5. Continue pressing CONFIG until the measured value display appears. Alternatively, pressOUTPUT or PWR DSPL. If you are configuring a slave unit, press CONFIG orPWR DSPL.Some CONFIG parameters will be applied immediately after you set them, some will beapplied after you restart the RMX programmable power supply, and some will be appliedafter you execute CF40 “APPL”.