33 Technical SpecificationsCAN ICES-3(A)/NMB-3(A)This device complies with part 15 of the FCC Rules. Operation is subject to the following twoconditions: (1) This device may not cause harmful interference, and (2) this device must acceptany interference received, including interference that may cause undesired operation.This equipment has been tested and found to comply with the limits for a Class A digital device,pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonableprotection against harmful interference when the equipment is operated in a commercialenvironment. This equipment generates, uses, and can radiate radio frequency energy and, if notinstalled and used in accordance with the instruction manual, may cause harmful interference toradio communications. Operation of this equipment in a residential area is likely to causeharmful interference in which case the user will be required to correct the interference at theirown expense.This Class A digital apparatus complies with Canadian ICES-003.Pursuant to EMC Directive – Article 9, this product is not intended for residential use.Table 1: System SpecificationsSupply Voltage (rated) 12VDCSupply Current (rated) 5AHydraulic Pressure (maximum) 3300 psiBaud Rate 250 kbpsClock Frequency (maximum) 96 MHzSolenoid Valve PWM Frequency 300 HzUltrasonic Sensor Transmit Frequency 50 kHzOperating Temperature Range 0°C to 80°CThe 5A fuse on the power cable may be replaced by the operator if needed. The replacementfuse must be rated to blow in less than 120 seconds at 200% and be ANSI/UL248-14 or better.Table 2: Replacement FuseNorac Part Number 106467Manufacturer Part Number Littelfuse - 0257005