MGC Serial Ports 27MGC serial port default configurationThe default settings for the serial ports are• Baud rate = 9600• Number of data bits = 8• Number of stop bits = 1• Parity = none• Flow control = noneMGC serial ports configuration change in Overly 17If you configure the serial ports on an MG 1000B with MGC as SL1 terminalson the Call Server, then the baud rate, number of data bits, number of stopbits, parity, and flow control are configured in LD 17.Any values configured in LD 17 are downloaded to the MGC and overridethe default values. The downloaded values are stored on the MGC andpersist over restarts and power outages. When the serial port baud rate ischanged, a system message indicates the change.CEMux SupportSupport of the Option 11C CS 1000M cabinet and chassis CEMux typecards are additions to the MG 1000B with an MGC with the CP PM. Thelist of supported cards is as follows:Table 2CEMux Packs and daughter boards supported in MG 1000B with MGCPack Daughterboard IP Expansion CEMux ApplicationDCHI (NTAK93) non-downloadable DCHDDCH (NTBK51) downloadable DCH1.5MB DTI/PRI(NTAK09)CC (NTAK20) clock controller (stratum 3/4)1.5MB TMDI(NTRB21)CC (NTAK20) downloadable DCH, clock controller (stratum 3/4)2.0MB DTI (NTAK10)n/a clock controller (stratum 3/4)2.0MB PRI (NTAK79) n/a clock controller (stratum 3/4), non-downloadableDCHDDCH (NTBK51) downloadable DCH2.0MB PRI (NTBK50)CC (NTAK20 clock controller (stratum 3/4)MISP (NTBK22) CC (NTAK20) MISP BRI processor, clock controller (stratum 3/4)SDI_DCH (NTAK02) n/a only DCH is supportedNortel Communication Server 1000Branch Office Installation and CommissioningNN43001-314 01.02 StandardRelease 5.0 20 June 2007Copyright © 2007, Nortel Networks.