356 Maintenance and diagnosticsThe CLIDVER report contains the CLID composed for the Branch User.If the report is generated on the main office Call Server, the CLID iscomposed as follows:• If ESA is enabled in the Branch Office, the CLID is the same as the valueentered for the ESA Locator parameter in the CHG ZESA command inLD 117 (see Procedure 37 "Configuring the main office" (page 319),step 5).• If ESA is not enabled, the CLID is the same as the CLID entry composedin LD 15 (see Procedure 9 "Configuring ESN and MG 1000B zones"(page 210), step 1).If the CLIDVER report is generated on the MG 1000B CP PM, the CLIDis the same as the CLID entry composed in LD 15 (see Procedure 23"Configuring the MG 1000B zone" (page 257), Step 2).Refer to Emergency Services Access: Description and Administration(NN43001-613) for more information on this feature.Print Branch Office zone informationLD 117 contains commands to view Branch Office zones at the main officeCall Server.LD 117 Print zone information.Command DescriptionPRT ZACB []Print a table of Branch Office zone dialing plan entries.PRT ZBW []Print a table of zone bandwidth utilization.PRT ZDES []Print a table of the zone description entries.PRT ZDP []Print a table of Branch Office zone dialing plan entries.PRT ZDST []Print a table of Branch Office zone time adjustment properties entries.PRT ZESA []Print a table of Branch Office zone Emergency Services Accessparameters.PRT ZONE ALL Print zone information for all zones.PRT ZONE 0-255 Print zone information for a specific zone.PRT ZTDF []Nortel Communication Server 1000Branch Office Installation and CommissioningNN43001-314 01.02 StandardRelease 5.0 20 June 2007Copyright © 2007, Nortel Networks.