Page 22 of 66 Agent Greeting Card Test and Debug CapabilitiesNTPH13AA_maint 3.01 February 2006In addition on Media Card Agent Greeting (NTVQ09BA), if the IXP1200encounters any failures during it’s initialisation, a “H:XX” error code appearson the hex display. The list of error codes are as follows:Debug Terminal AccessThe Agent Greeting Card Debug Terminal access is provided via an RS-232port. This is accessible via the NTAG81CA faceplate serial cable. Messagesindicating the completion of each self test phase, as well as any detected faultswill be logged to this serial port.The pinouts for the Mini-DIN Connector, to which the faceplate serial (akamaintenance) cable connects, are given in Table 4 on page 22.The terminal connected to the serial port requires these settings: 9600bps, 8data bits, 1 stop bit, no parity, and no flow control.Table 3: IXP1200 Initialisation hex display error codesDisplay Code DescriptionH:00 IXP1200 not bootingH:01 SDRAM test failureH:02 SRAM test failureH:04 PCMCIA device failureH:08 Network interface failureH:10 Meridian interface failureH:20 DSP interface failureH:40 NVRAM/EEPROM interface failureH:80 PCM connector failureTable 4: Faceplate Mini-DIN Connector pinoutPin No. Signal Dir Description1 BDTRB- O Port B Data Terminal Ready