Mediant 2000 SIPMediant 2000 SIP User’s Manual 136 Document #: LTRT-72504• [CALL PROGRESS TONE #X] – containing the Xth tone definition (starting from 1 and notexceeding the number of Call Progress Tones defined in the first section) using the followingkeys:¾ Tone Type – Call Progress Tone typeFigure 7-1: Call Progress Tone Types1. Dial Tone2. Ringback Tone3. Busy Tone7. Reorder Tone17.Call Waiting Ringback Tone23. Hold Tone¾ Low Freq [Hz] – Frequency in hertz of the lower tone component in case of dualfrequency tone, or the frequency of the tone in case of single tone.¾ High Freq [Hz] – Frequency in hertz of the higher tone component in case of dualfrequency tone, or zero (0) in case of single tone.¾ Low Freq Level [-dBm] – Generation level 0 dBm to –31 dBm in [dBm].¾ High Freq Level – Generation level. 0 to –31 dBm. The value should be set to ‘32’ inthe case of a single tone.¾ First Signal On Time [10 msec] – “Signal On” period (in 10 msec units) for the firstcadence on-off cycle.¾ First Signal Off Time [10 msec] – “Signal Off” period (in 10 msec units) for the firstcadence on-off cycle.¾ Second Signal On Time [10 msec] – “Signal On” period (in 10 msec units) for thesecond cadence on-off cycle.¾ Second Signal Off Time [10 msec] – “Signal Off” period (in 10 msec units) for thesecond cadence on-off cycle.¾ Default Duration [msec] - The default duration (in 1 msec units) of the generated tone.Note 1: When the same frequency is used for a continuous tone and a cadence tone,the ‘Signal On Time’ parameter of the continues tone must have a value thatis greater than the ‘Signal On Time’ parameter of the cadence tone.Otherwise the continues tone is detected instead of the cadence tone.Note 2: The tones frequency should differ by at least 40 Hz from one tone to otherdefined tones.For example: to configure the dial tone to 440 Hz only, define the following text:Figure 7-2: Defining a Dial Tone Example#Dial tone[CALL PROGRESS TONE #1]Tone Type=1Low Freq [Hz]=440High Freq [Hz]=0Low Freq Level [-dBm]=10 (-10 dBm)High Freq Level [-dBm]=32 (use 32 only if a single tone is required)First Signal On Time [10msec]=300; the dial tone is detected after 3 secFirst Signal Off Time [10msec]=0Second Signal On Time [10msec]=0Second Signal Off Time [10msec]=0