COMMAND DEFAULT NOTEPrint Rotation 0 o (1)Vertical Reference Point 0 (1)Horizontal Reference Point 0 (1)Character Pitch 2 (1)Base Reference Point H=0, V=0 (2)Character Expansion 1 (1)Print Darkness 200 (1)Print Speed 3 ips (2)Notes:(1) The settings for these commands will revert to the default values when the printer receives an Z or an*.(2) These values transmitted with these commands will remain in effect until a new command is received.PRINTER CONFIGURATIONThe OKIPOS X400 printers are different from other OKI models in that they do not use DIP switches for printerconfiguration. Instead, all printer configuration is done via software commands. The parameters that can beconfigured are:z Sensor Calibrationz Protocol Codesz Print Darkness Rangez Sensor Typez RS232 Parametersz Label Tear-Off Positionz Backfeed Enable/DisableBecause there are no DIP switches to indicate the current printer settings, a Test Label can be printed that liststhe active settings in the printer. This Test Label lists all of the information a user needs to ascertain the printerconfiguration. Test Labels can be printed out by sending a command by software (see page 92) or by using theFEED button (see User’s Guide).LABEL SENSINGThe OKIPOS X400 printers can use eye-mark (black bar), gap or notch label sensing. The gap and notch sensoris a transmissive or see-thru type with an infrared light source directed through the label from above anddetected by a separate sensor underneath the label. A reflective sensor is used to detect eye-marks printed on the9All manuals and user guides at all-guides.comall-guides.com