Set Sensor TypeCommand Structure CIaa = 0 Disables Sensor.1 Reflective (Eye-Mark) Sensing.2 Transmissive (Label Gap or Notch) Sensing.Example: CI0Placement: This command should be sent in a separate data stream.Default: CI2 (Transmissive Sensing)Command Function To select the top-of-label sensing method.Input to Printer ACI2ZPrinter Output There is no printer output as a result of this command.Special Note The reflective Eye-Mark, label gap or notch must be a minimum of 2 mm wide andextend 10 mm from the left (facing the printer) edge of the label backing.96All manuals and user guides at all-guides.com