69 (E)CONTENTSError messagesError messagesE-55UNLOADERRORIf the tape has not been taken up duringunloading, this error number flashes on thedisplay.VTR: STOPOSet the POWER switch to OFF and then toON again.E-53WINDUPERRORIf there is an abnormally large discrepancybetween the amount of tape taken up by thetake-up reel and the amount of tape supplied bythe supply reel while the tape is travelling afterthe total amount of the tape begins to bedetected, this error number flashes on thedisplay.VTR: STOPOSet the POWER switch to OFF and then toON again.E-52W-UP REELNOT ROTAIf the take-up reel fails to take up the tape whilethe tape is travelling in the state where the totalamount of the tape has not yet been detectedafter the cassette was inserted, this errornumber flashes on the display.VTR: STOPOSet the POWER switch to OFF and then toON again.E-38SERVO FGERRORIf automatic adjustment of the reel and capstanrotation in eject status was not performedcorrectly when the power was turned on, thiserror number flashes on the display.VTR: STOPOSet the POWER switch to OFF and then toON again.Display ODescriptionOVTR operation and corrective actionE-29FRONT LOADMOTORThe unit switches to eject mode and if thecassette fails to move up within 6 seconds, thiserror number flashes on the display.OIf the cassette does not move down inside themachine even when 6 seconds have elapsedsince the cassette was inserted, the VTR istransferred to the eject mode.VTR: STOPOSet the POWER switch to OFF and then toON again.E-20DEWIf condensation is detected, the error numberflashes and the unit transfers to eject mode. Thedrum rotates after the cassette is ejected toeliminate the condensation.Once the unit is released from condensationstatus, the error message display is cleared andthe VTR is able to be used.OIf condensation is detected in the eject mode,the drum starts rotating as soon as it isdetected.OIf condensation is detected when the cassettehas been inserted, the drum rotation isstopped, and after the tape is ejected, thedrum starts rotating.VTR: EJECTOLeave the power on and wait.Display ODescriptionOVTR operation and corrective actionE-31LOADINGMOTORIf the unloading operation is not completedwithin 6 seconds, this error number flashes onthe display.OWhen the loading operation is not completedwithin 6 seconds, the VTR is transferred to theeject (unloading) mode.VTR: STOPOSet the POWER switch to OFF and then toON again.E-37SERVO COMMERRORIf 10 seconds or more elapses and the servomicrocomputer has not followed orders issuedby the system control microcomputer, this errornumber flashes on the display.VTR: STOPOSet the POWER switch to OFF and then toON again.E-35SERVOCONTROLERRORIf there is no response from the servomicrocomputer for 1 second or more, this errornumber flashes on the display.VTR: STOPOSet the POWER switch to OFF and then toON again.E-57S-FF/REWTIMEOVERIf the start or end processing operation is notcompleted, this error number flashes on thedisplay.VTR: STOPOSet the POWER switch to OFF and then toON again.E-51FRONT LOADERRORIf the take-up reel rotates without engaging for aspecific period of time during the start or endprocessing operation while loading is underway(half position), this error number flashes on thedisplay.VTR: STOPOSet the POWER switch to OFF and then toON again.E-60DRUM ROTATOO FASTIf the cylinder motor speed is abnormally high,this error number flashes on the display.VTR: STOPOSet the POWER switch to OFF and then toON again.E-59DRUM ROTATOO SLOWIf the cylinder motor speed is abnormally low,this error number flashes on the display.VTR: STOPOSet the POWER switch to OFF and then toON again.E-61CAP ROTATOO SLOWIf the capstan motor speed is abnormally low,the error number flashes on the display.VTR: STOPOSet the POWER switch to OFF and then toON again.