Installation InstructionsStanding installationThe procedure is the same as for suspended installation. For further details on installation and connection, refer to (→ pages 9 to 11).• For the standing installation, the bracket attachment procedure differs from that for the suspended installation. Attach the mount bracket in referenceto page 8 before performing this work.1. Check the mounting space. (→ page 9)• As with installing the unit suspended from an overhead surface, carefully check the space where the unit will be mounted, and then decide if it isappropriate to install the unit in that space.2. Attach mount bracket B onto the installation surface. (→ page 10)Bracket mounting screws A(M4 x 10 mm, binder‑head)3. Attach the drop‑prevention wire. (→ page 10)4. Mount the unit. (→ page 11)• Align the hole for checking the positioning of mount bracket B with the positioning mark of the unit.• Align the bottom insertion holes of the unit with the camera insertion protrusions of the bracket and then push the unit and bracket together firmlyand rotate the unit by approx. 20° in the direction of the arrow.• Secure the unit and mount bracket B with the supplied bracket mounting screw B (M3 x 6 mm).Bracket mountingscrew B (M3 × 6 mm)Positioning markApprox.20°On the unit:Bottom insertionholes(3 places)On the mountbracket:Camera insertionprotrusions (3 places)Hole for checkingthe positioning5. Check the mounting. (→ page 11)6. Connect the rear panel connectors. (→ page 11)13How to install and connect the unit (continued)