3512.2 Indoor Fan Motor Operation12.2.1 CS-VE9NKEIndicates the changeable range using the remote controlStop SSLo SLo Quiet Lo Lo- Lo Me- Me Hi SHiFan speed: Manual O 480 540 580 580 660 820 980 1100 ~1180 ---Outside temperature is below 35°C or Neuro isstable.Outside temperature is 35°C or higherand Neuro is unstable.Normal (with programmed air) OMIN 590 ± 50 ~ 860 ± 50rpm 940 ± 50rpmPowerful 1230 (SHi) (1180 when the setting is changed from Hi to Powerful on the remote control.)Long Right/Left 1290 (SHi) (1180 when the setting is changed from Hi to Long on the remote control.)Long Other thanRight/Left 1250 (SHi) (1180 when the setting is changed from Hi to Long on the remote control.)InitialairflowWhen the area controlis in operation 980Powerful 640 1030Long Right/Left 660 1070Long Other thanRight/Left 660 1050COOL / COOL RangeAirflowstable /unstableWhen the area controlis in operation (1) 640 1030Normal Cool dry O Range 2 540 Range 1 660Powerful/Long 660Initialairflow When the area controlis in operation 980Powerful/Long 540 760COOL DRYRangeFanspeed:AutoAirflowstable /unstable When the area controlis in operation (1) 540 760Fan speed: Manual O --- --- 550 --- 690 790 890 990 ---Normal 710At the start ofoperation 1230Powerful /Long Not at the start ofoperation 1090When the area control is inoperation Min. rotation speed for each of the following fieldsFull DryFanspeed:AutoClothes drying 1230Fan speed: Manual O 380 540 650 650 730 890 1050 1240 ~1300 ---Unstable 830 1100Normal Stable 910 1100Powerful 830 1220 (1300 when the setting is changed from Hi to Powerful on the remotecontrol.)Long Right/Left 830 1400 (1300 when the setting is changed from Hi to Long on the remote control.)Long Other thanRight/Left 830 1240 (1300 when the setting is changed from Hi to Long on the remote control.)InitialairflowWhen the area controlis in operation 830 1220Powerful 950 1050Long Right/Left 970 1090Long Other thanRight/Left 970 1070HEATFanspeed:AutoAirflowstable /unstableWhen the area controlis in operation (1) 950 1050Hot Dry max 730Fan speed: Manual O 580 660 820 980 1150 ---Individual ventilation /NANOE Fan speed: Auto 500Odor Cut ShiftOnly for the COOL and COOL range Below Lo: No shifting Below Me and fan speed auto: 20 Me and above: 90* Lock detection: When the rotation speed of 2550rpm and above or below 50rpm is detected for 10 consecutive seconds during the feedbackcontrol, H19 is indicated (the TIMER indicator flashes) if normal rotation speed is not detected even after the retry is performed 7 times.* Refer to the attached list of “Indoor Unit Fan Operation Status” for the operations of the indoor unit fan while the thermostat is OFF.