4312.10 nanoe-G Operation This operation provides clean air by producing great amount of negative ions and distribute through thedischarge airflow to capture or deactivate molds, bacteria or viruses. nanoe-G ON/OFF conditionPriority Item Output“No NANOE-G” is selected during model selection.During Demo modeTwo-way communications on remote controlNANOE-G connector open1NANOE-G error (circuit error & abnormal discharge detection)OFFInspection mode NANOE-G ON command ON2 Inspection mode NANOE-G OFF command OFFNo “NANOE-G” setting on the remote controlOperation status: OFFDuring NANOE-G restart prohibiting time(Prohibiting time is set in the case of abnormal discharge and room temperature of 40°Cand above. Details will be provided later.)3During FM OFF; or FM rotation speed is less than 490 rpmOFFLess than 60 minutes have elapsedsince the start of Powerfulindividual fan operation.ONOrdinary vertical louver selected; or Airflowdirection is not set to ceiling airflow or DOWN Other than above4Twin louver is selected; or airflow direction is ceiling airflow or DOWN ON/OFFintermittent outputas mentionedbelow ON/OFF intermittent output nanoe-G operation pause conditiono When indoor fan stop (during deice, odor cut control, thermostat off, etc.). nanoe-G operation resume afterindoor fan restarts.o When indoor intake temperature ≥ 40°C. nanoe-G operation resume after indoor intake temperature ≤ 40°Ccontinuously for 30 minutes. Indoor fan controlo During any operation mode combines with nanoe-G operation, fan speed follows respective operation mode.However, nanoe-G system enabled when fan speed ≥ 490 rpm to ensure proper negative ion distribution,nanoe-G system disabled when fan speed < 490 rpm. Airflow direction controlo During any operation mode combines with nanoe-G operation, airflow direction follows respective operationmode.o During nanoe-G individual operation, only Auto Air Swing is allowed. Even if Air Swing button is pressed, nosignal is sent to the unit and no change on remote control display. Timer controlo When ON Timer activates when unit stops, previous operation resumes and restored last saved nanoe-Goperation status.o When ON Timer activates during any operation, no change on current operation.o When OFF Timer activates during any operation, all operation stops and the latest nanoe-G operation statusis saved. Indicatoro When nanoe-G starts, nanoe-G indicator ON.