4212.7.3 Sleep Timer Sleep operation is performed according to the delay OFF time (0.5, 1, 2, 3, 5, 7 or 9 hr) and provide comfortableenvironment by shifting set temperature.Heating Cooling, DryA 2hr 3hrB *5am *4am* According to remote control clockTemperature ShiftStatus 1 Status 2 Status 3 Status 4Cooling 0 +1 +2 +3Set temperature (°C) Heating 0 -1 -2 -3Stop condition- Reached delay time.- Pressed sleep button to cancel.- Unit is OFF.12.8 Auto Restart Control When the power supply is cut off during the operation of air conditioner, the compressor will re-operate withinthree to four minutes (there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to beselected randomly) after power supply resumes. This type of control is not applicable during ON/OFF Timer setting. This control can be omitted by open the circuit of JP1 at indoor unit printed circuit board.12.9 Indication PanelLED POWER TIMER +8/10°C HEAT nanoe-G ECONAVIColor Green Orange Green Blue GreenLight ON Operation ON Timer Setting ON +8/10°C HEATMode ONnanoe-GON ECONAVI ONLight OFF Operation OFF Timer Setting OFF +8/10°C HEATMode OFFnanoe-GOFF ECONAVI OFFNote: If POWER LED is blinking, the possible operation of the unit are Hot Start, during Deice operation, operationmode judgment, or ON timer sampling. If Timer LED is blinking, there is an abnormality operation occurs.