4912.12.2.1 Demo ModeThe air conditioner starts the operation in the Demo mode as described below when 2 minutes have elapsed after theprotection control was started subsequent to the confirmation of communication error.(At this time, a strong warning sound is emitted for 3 minutes if the test run memory is “incomplete”.)Condition to stop the modeThe operation is stopped by turning off the air conditioner on the remote control or pressing the EMERGENCYOPERATON switch during the Demo mode.(“TIMER” LED flashes.)Zone B Airflow Unit Operation Mode (Normal Operation)Transition time to DemoMode180sec fromthe demo starts360 sec fromthe demo starts540 sec fromthe demo starts640 sec fromthe demo starts[POWER] LED ON OFF[NANOE-G] LED Follow the remote control settings OFF[+8/10°C HEAT] LED Follow the remote control settings OFF[ECONAVI] LED Follow the remote control settings OFF[TIMER] LED Auto Demo mode is set during the model selection: Follow the remote control settings.When in Product Demo mode: Always OFF (Timer is cancelled due to H11)Front panel STM Open Stop positionVertical louver STM Ceiling airflow Heating 5 Swing Stop positionHorizontal louver STM Area OFF or Auto Demo is set: Swing from the front sideOthers: Area control under Heating, Range B, Airflow stable ResetFan motorFan speed is set to Auto on the remote control: OFFFan speed is set to Manual on the remote control: Remote controllersetting tapStop positionHuman activity sensor Area ON: Repeat the scan detection and fixed detection.Area OFF: Standby position (Default position)Standby position(Default position)Sunlight sensor LED brightness changes (Bright-Dim) when ECONAVI is ON. Confirmed time is for Demo only.NANOE output OFF12.12.2.2 Infrared Sensor Abnormality Abnormality detection: Connector disconnection / Wire cut abnormalityo Sensor judge Hi level continuously for 25 seconds Circuit abnormalityo 65 seconds after power ON, if infrared sensor judge Lo level continuously for 25 seconds Error Code judgment When abnormality happened, internal counter increase by 1 time. Infrared sensor power OFF, retry after 5 seconds. When the infrared sensor maintains normal condition for 120 seconds, the counter reset or AC reset. When abnormality counter reached 4 times, H59 occurred – No TIMER indicator blinking. When error code happened, the unit is able to operate without ECONAVI / AUTO COMFORT.12.12.2.3 Infrared Sensor Check Mode1 Conditions to start the modeThe infrared sensor check mode starts when all of the following conditions are met:o The infrared sensor error is not being detected.o Not in Demo mode.o Human activity sensor is not selected.o An error of Error Level 20 or higher is not present.o The signal for infrared sensor check is received. (Long-press the “AUTO COMFORT” button on theremote control for 10 seconds)2 Conditions to end the modeThe infrared sensor check mode ends when any of the following conditions is met:o A signal other than the signal for infrared sensor check is received; or the EMERGENCY button ispressed → The signal received is followed.o 5 minutes have elapsed since the signal for infrared sensor check was received → The mode is stopped.o The infrared sensor error is confirmed → The mode is stopped.o An error of Error Level 20 or higher has occurred → Follow the processing of each error.