154DP-8032/80252008Ver.1.2E5: System ErrorCode Function Possible Cause(s)E5- 05 Vp (+24V, Scanner) 1. SDR PCB connector disconnected.2. SDR PCB defective.3. SPC PCB connector disconnected.4. SPC PCB defective.5. LVPS defective.E5- 11 Printer EngineCommunication Abnormal1. SPC PCB connector disconnected.2. SPC PCB defective.3. SC PCB connector disconnected.4. SC PCB defective.E5- 12 Scanner EngineCommunication AbnormalE5- 17 Scanner SynchronizationE5- 19 Scanner LineSynchronizationE5- 22 Finisher communication 1. SPC PCB connector is disconnected (CN724).2. SPC PCB is defective.3. IPC PCB is disconnected.4. IPC PCB is defective.5. Finisher Interface Cable is disconnected.6. OP LVPS connector is disconnected (CN64, 65, 66).7. OP LVPS is defective.8. DC PCB connector is disconnected (CN144).9. Finisher is defective.E5- 42 Total Counter Connection 1. Total Counter connector disconnected.2. Total Counter defective.3. SPC PCB connector disconnected.4. SPC PCB defective.E5- 60 Power Supply Cooling FanMotor Rotation1. Cooling Fan connector disconnected.2. Cooling Fan defective.3. SPC PCB connector disconnected.4. SPC PCB defective.5. LVPS defective.E7: Optional Unit Error (DA-FS300)Code Function Possible Cause(s)E7- 22 Finisher Damper Motor 1. Motor Connector disconnected.2. Motor defective.3. Home Position Sensor Connector disconnected.4. Home Position Sensor defective.5. Gear defective.E7- 23 Finisher Staple Motor 1. Motor Connector disconnected.2. Motor defective.3. Home Position Sensor Connector disconnected.4. Home Position Sensor defective.5. Micro Switch Harness disconnected.6. Micro Switch defective.7. Solenoid Harness disconnected.8. Solenoid defective.9. Gear defective.10. Motor wedged with a jammed Staple.