Panasonic Digital Fiber Sensor FX-301 Specification Sheet
Contents |
79FX-301FD-EG1FD-EG2FD-EG3FD-E12FD-E22FD-EN500S1FD-ENM1S1LIST OF FIBERSSpecial useWide beamArrayHigh precisionUltra-small diameterLiquid level sensingTough flexible Fixed-focus reflectiveSpecial use fibers (Reflective type):LONG:STD :FAST:S-DSensing range (mm in) (Note 1, 2)Red LED Blue LED Green LED Infrared LED200 7.874150 5.906100 3.93750 1.96938 1.49618 0.70914 0.551220 8.661110 4.33178 3.07139 1.535110 4.33155 2.16542 1.65419 0.7486 0.23625 0.98412 0.4729 0.3545 0.19715 0.5918 0.3155 0.1973 0.11811 0.4336 0.2364 0.1571 0.03945 1.77223 0.90617 0.6697 0.2765 0.1973 0.1182 0.079Cannot use38 1.49618 0.70914 0.5516 0.2360 to 20 0 to 0.7872.5 to 18 0.098 to 0.709 (Convergent point 8 0.315)3 to 16 0.118 to 0.630 (Convergent point 8 0.315)3.5 to 15 0.138 to 0.591 (Convergent point 8 0.315)Cannot use0.5 to 4 0.020 to 0.157 (Convergent point 2 0.079)1 to 3.8 0.039 to 0.150 (Convergent point 2 0.079)1.3 to 3.5 0.051 to 0.138 (Convergent point 2 0.079)Cannot use2.5 to 18 0.098 to 0.709 (Convergent point 6 0.236)4 to 12 0.157 to 0.472 (Convergent point 6 0.236)4.5 to 11 0.177 to 0.433 (Convergent point 6 0.236)4.8 to 9.5 0.189 to 0.374 (Convergent point 6 0.236)185 7.28380 3.15035 1.37890 3.54345 1.77260 2.36235 1.37820 0.787Notes: 1) The sensing range is specified for white non-glossy paper [100100 mm 3.9373.937 in (FD-A15, FD-G4, FD-G6X: 200200 mm 7.8747.874 in,FD-AFM2, FD-AFM2E, FD-P81X: 400400 mm 15.74815.748 in, FD-L43: glass substrate 7652t 1.1 mm 2.9922.047t 0.043 in, FD-L41:glass substrate 100100t 2 mm 3.9373.937t 0.079 in)] as the object.Notes: 2) Please take care that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. In addition, theinfrared type is easily affected by humidity, so contact our office if using these sensors in environments with high humidity or where humidity levels canfluctuate.Notes: 3) The minimum sensing object size is the value for red LED type at maximum sensitivity. Please contact our office for information on the minimum sensingobject size if using amplifiers other than red LED type.Also, note that the corresponding setting distance is different from the rated sensing distance. However, with the fixed-focus reflective type, when thesensitivity is at MAX., it is only possible to detect the minimum size of the sensing object at a distance corresponding to the convergent point.Notes: 4) Following is the allowable cutting range from the end that the amplifier is inserted FD-F8Y: 1,000 mm 39.370 in, FD-G6X: 700 mm 27.559 in.Allowablebendingradius Model No.25 0.98415 0.59140 1.57520 0.78713 0.51222 0.86611 0.4338 0.3156 0.2363 0.1182 0.0795 0.1972 0.0791 0.0392 0.0791 0.0392 0.0791 0.0396 0.2363 0.1182 0.0796 0.2363 0.1182 0.0794.5 to 9.5 0.177 to 0.3745 to 9 0.197 to 0.3545.5 to 8 0.217 to 0.31532 1.26016 0.63010 0.39422 0.86611 0.4336 0.23618 0.7099 0.3545 0.19712 0.4726 0.2364 0.1573 0.1181.5 0.0591 0.0392 0.0791 0.0391 0.0391 0.0393 0.1181.5 0.0591 0.0393 0.1181.5 0.0591 0.03912 0.4726 0.2364 0.1577 0.2763.5 0.1382 0.07910 0.3945 0.1973 0.1186 0.2363 0.1182 0.0793 0.1181.5 0.0591 0.0391 0.0396 0.2363 0.1182 0.0794 0.1572 0.0791.5 0.0595 to 9 0.197 to 0.3545.5 to 8 0.217 to 0.3154.5 to 9.5 0.177 to 0.37416 0.6308 0.3155 0.19712 0.4726 0.2364 0.15730 1.18115 0.59110 0.39418 0.7099 0.3545 0.197"0.02 mm"0.0008 ingold wire"0.02 mm"0.0008 ingold wire"0.02 mm"0.0008 ingold wire"0.06 mm"0.0024 ingold wire"0.03 mm"0.0012 ingold wire"0.02 mm"0.0008 ingold wire"0.02 mm"0.0008 ingold wire(LCD glass)(Liquid)(Liquid)"0.04 mm"0.0016 ingold wire"0.02 mm"0.0008 ingold wireFD-A15FD-L41FD-L42FD-L4FD-P81XFD-G6XFD-AFM2FD-AFM2EFD-G4FD-G6FD-L43FD-F8YFD-F41FD-F91FD-F4FD-F9500 mm19.685 in1 m3.281 ft500 mm19.685 in1 m3.281 ft1 m3.281 ft2 m6.562 ft5 m16.404 ft2 m6.562 ft5 m16.404 ftR10 mmR0.394 inR10 mmR0.394 inR4R0.157R10 mmR0.394 inR10 mmR0.394 inR10 mmR0.394 inR25 mmR0.984 inR25 mmR0.984 inR25 mmR0.984 inR25 mmR0.984 inProtective tubeR40 mm R1.575 inFiberR15 mm R0.591 inApplicable pipe diameter:Outer dia. "6 to "26 mm "0.236 to "1.024 in transparent pipe[PVC, fluorine resin, polycarbonate, acrylic, glass, wall thickness 1 to 3 mm 0.039 to 0.118 in]Applicable pipe diameter:Outer dia. "6 to "26 mm "0.236 to "1.024 in transparent pipe[PFA (fluorine resin) or equivalently transparent pipe, wall thickness 1 mm 0.039 in]W7H15D30 W0.276H0.591D1.181Top sensingW5H20D20W0.197H0.787D0.787Side sensingW5H20D20W0.197H0.787D0.787Coaxial Lens mountableCoaxial Lens mountableCoaxial Lens mountableCoaxial Lens mountableCoaxial Lens mountableCoaxialCoaxialSleeve part cannot be bent.Sleeve part cannot be bent.Sleeve part cannot be bent.Sleeve part cannot be bent.Glass substrate detectionSEMI S2 compliantW17H29D3.8W0.669H1.142D0.150Glass substrate detectionW24H21D4W0.945H0.827D0.157Specular object detectionW15H19D3W0.591H0.748D0.118W6H18D14W0.236H0.709D0.551Mountable on pipeStandardW25H13D20W0.984H0.512D0.787Mountable on pipe For PFA, wallthickness 1 mm 0.039 in pipeW25H13D20W0.984H0.512D0.787Contact type"6 "0.236Small spot for sensing minute objectsCoaxial High precisionType Shape of fiber head(mm in)Min. sensing objectat the maximumsensitivity (Note 3)2 m6.562 ft2 m6.562 ft2 m6.562 ft2 m6.562 ft2 m 6.562 ft(Note 4)1 m 3.281 ft(Note 4)Fiber cablelength: Free-cut |
Related manuals for Panasonic Digital Fiber Sensor FX-301
Panasonic MA Motion Sensor Series Specification Sheet
Panasonic MA4SD01 Specification Sheet
Panasonic MA27P01 Specification Sheet
Panasonic MA3SE01 Specification Sheet
Panasonic MA2SP01 Specification Sheet
Panasonic MA24F70 Specification Sheet
Panasonic MA2SP05 Specification Sheet
Panasonic MA22D39 Specification Sheet
Panasonic MA27P06 Specification Sheet
Panasonic MA24D50 Specification Sheet
manualsdatabase
Your AI-powered manual search engine